R&S <strong>FSQ</strong> Instrument Functions<br />

<strong>Analyzer</strong> Mode<br />

NEW SEARCH The NEW SEARCH softkey starts a new peak search and adds the results to the<br />

peak list. Note that you have to activate the peak list before results are visible.<br />

PEAK LIST<br />

(ON OFF)<br />

AUTOSEARCH<br />

(ON OFF)<br />

SORT MODE<br />

(FREQ LEVEL)<br />

PEAK<br />

EXCURSION<br />

SEARCH<br />

LIMITS<br />

LEFT LIMIT |<br />

RIGHT LIMIT<br />

The peak search is based on the current content of the trace buffer. Therefore, you<br />

may encounter unexpected results in continuous or single sweep if you start a peak<br />

search without the sweep being finished as parts of the trace may not have been<br />

updated yet.<br />

Remote command: INIT;*WAI;<br />

CALC:MARK:FUNC:FPE 10;<br />

CALC:MARK:FUNC:FPE:COUN?;<br />

CALC:MARK:FUNC:FPE:Y?;<br />

CALC:MARK:FUNC:FPE:X?<br />

Activates and deactivates the peak list that is displayed below the diagram area.<br />

The peak list is always available for a query in remote operation after a search has<br />

been performed, even if it is inactive.<br />

Remote command: CALC:MARK:FUNC:FPE:STAT ON | OFF<br />

Activates or deactivates an automatic peak search. The R&S <strong>FSQ</strong> performs the<br />

automatic peak search after it has finished a sweep.<br />

If you need an update of the peak list prior to the end of the sweep, perform a new<br />

search with the NEW SEARCH softkey.<br />

Remote command: CALC:MARK:FUNC:FPE:SEAR:AUTO ON | OFF<br />

The SORT MODE (FREQ LEVEL) softkey defines the position of the peak values in<br />

the list:<br />

• FREQ: sorting in ascending order of frequency values (time values if span = 0)<br />

• LEVEL: sorting according to level<br />

Remote command: CALC:MARK:FUNC:FPE:SORT X;<br />

With level measurements, the PEAK EXCURSION softkey allows the minimum<br />

amount to be entered by which a signal must decrease or increase in order to be<br />

recognized as a maximum by the peak search function.<br />

Values between 0 dB and 80 dB may be entered, the resolution being 0.1 dB<br />

Remote command: CALC:MARK:PEXC 6dB<br />

Opens a submenu to define peak search search limits.<br />

LEFT LIMIT | RIGHT LIMIT<br />

THRESHOLD<br />

SEARCH LIM OFF<br />

The LEFT LIMIT and RIGHT LIMIT softkeys define the vertical lines F1/F2 in the frequency<br />

domain (span > 0) and T1/T2 in the time domain (span = 0) between which<br />

the search is carried out.<br />