R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

[SENSe:]POWer:TRACe 1 to 3<br />

SENSe Subsystem<br />

This command assigns the channel/adjacent channel power measurement to the indicated trace in the<br />

selected measurement window. The corresponding trace must be active, i.e. its state must be different<br />

from blank.<br />

Example: "POW:TRAC 2"<br />

'Assigns the measurement in screen A to trace 2.<br />

"SENS2:POW:TRAC 3"<br />

'Assigns the measurement in screen B to trace 3.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

The measurement of the occupied bandwidth (OBW) is performed on the trace on<br />

which marker 1 is positioned. To evaluate another trace, marker 1 must be positioned<br />

to another trace with CALCulate:MARKer:TRACe.<br />

Operating Manual 1313.9681.12 - 01 6.203