R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Alphabetical List of Remote Commands<br />

Command Parameter Page<br />

CALCulate:LIMit:ACPower:ACHannel[:RELative] 0 to 100dB, 0 to 100dB 6.31<br />

CALCulate:LIMit:ACPower:ACHannel[:RELative]:STATe ON | OFF 6.31<br />

CALCulate:LIMit:ACPower:ACHannel:RESult? 6.32<br />

CALCulate:LIMit:ACPower:ALTernate:ABSolute -200DBM to 200DBM, -200DBM to<br />

200DBM<br />

CALCulate:LIMit:ACPower:ALTernate:ABSolute:<br />

STATe<br />

ON | OFF 6.33<br />

CALCulate:LIMit:ACPower:ALTernate[:RELative] 0 to 100dB, 0 to 100dB. 6.34<br />

CALCulate:LIMit:ACPower:ALTernate[:RELative]:<br />

STATe<br />

ON | OFF 6.34<br />

CALCulate:LIMit:ACPower:ALTernate:RESult? 6.35<br />

CALCulate:LIMit:ACPower[:STATe] ON | OFF 6.36<br />

CALCulate:LIMit:ACTive? 6.26<br />

CALCulate:LIMit:CATalog? 6.26<br />

CALCulate:LIMit:CLEar[:IMMediate] 6.27<br />

CALCulate:LIMit:COMMent 6.27<br />

CALCulate:LIMit:CONTrol[:DATA] ,. 6.37<br />

CALCulate:LIMit:CONTrol:DOMain FREQuency | TIME 6.37<br />

CALCulate:LIMit:CONTrol:MODE RELative | ABSolute 6.37<br />

CALCulate:LIMit:CONTrol:OFFSet 6.38<br />

CALCulate:LIMit:CONTrol:SHIFt 6.38<br />

CALCulate:LIMit:CONTrol:SPACing LINear | LOGarithmic 6.38<br />

CALCulate:LIMit:COPY 1 to 8 | 6.27<br />

CALCulate:LIMit:DELete 6.28<br />

CALCulate:LIMit:FAIL? 6.28<br />

CALCulate:LIMit:LOWer[:DATA] ,... 6.39<br />

CALCulate:LIMit:LOWer:MARGin 6.39<br />

CALCulate:LIMit:LOWer:MODE RELative | ABSolute 6.39<br />

CALCulate:LIMit:LOWer:OFFSet 6.40<br />

CALCulate:LIMit:LOWer:SHIFt 6.40<br />

CALCulate:LIMit:LOWer:SPACing LINear | LOGarithmic 6.40<br />

CALCulate:LIMit:LOWer:STATe ON | OFF 6.40<br />

CALCulate:LIMit:LOWer:THReshold 6.41<br />

CALCulate:LIMit:NAME 6.28<br />

CALCulate:LIMit:STATe ON | OFF 6.28<br />

CALCulate:LIMit:TRACe 1 to 3 6.29<br />

CALCulate:LIMit:UNIT DBM | DBPW | WATT | DBUV | DBMV |<br />

VOLT | DBUA | AMPere | DB | UNITLESS<br />

6.29<br />

CALCulate:LIMit:UPPer[:DATA] ,... 6.42<br />

CALCulate:LIMit:UPPer:MARGin 6.42<br />

CALCulate:LIMit:UPPer:MODE RELative | ABSolute 6.42<br />

CALCulate:LIMit:UPPer:OFFSet 6.43<br />

CALCulate:LIMit:UPPer:SHIFt 6.43<br />

CALCulate:LIMit:UPPer:SPACing LINear | LOGarithmic 6.43<br />

CALCulate:LIMit:UPPer:STATe ON | OFF 6.43<br />

CALCulate:LIMit:UPPer:THReshold 6.44<br />

CALCulate:MARKer:AOFF 6.45<br />

CALCulate:MARKer:COUNt:RESolution 0.1 | 1 | 10 | 100 | 1000 | 10000 Hz 6.46<br />

CALCulate:MARKer:FUNCtion:CENTer 6.54<br />

CALCulate:MARKer:FUNCtion:CSTep 6.54<br />

CALCulate:MARKer:FUNCtion:DEModulation:CONTinuous ON | OFF 6.54<br />

CALCulate:MARKer:FUNCtion:DEModulation:HOLDoff 10ms to 1000s 6.55<br />

CALCulate:MARKer:FUNCtion:DEModulation:SELect AM | FM 6.55<br />

CALCulate:MARKer:FUNCtion:DEModulation:SQUelch:<br />

LEVel<br />

0 to 100 PCT 6.55<br />

Operating Manual 1313.9681.12 - 01 6.331<br />

6.33