R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Differences in GPIB Behavior between the FSP and the FSE Families of Instruments<br />

Devices Command (Sheet 21 of 47) Parameter Notes<br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

FSE DISPlay[:WINDow]:TRACe:X:<br />

SPACing<br />

FSE DISPlay[:WINDow]:TRACe:X[:<br />

SCALe]:RVALue<br />

FSE DISPlay[:WINDow]:TRACe:X[:<br />

SCALe]:ZOOM<br />

FSE DISPlay[:WINDow]:TRACe:X[:<br />

SCALe]:ZOOM<br />

[:FREQuency]:CENTer<br />

FSE DISPlay[:WINDow]:TRACe:X[:<br />

SCALe]:ZOOM<br />

[:FREQuency]:STARt<br />

FSE DISPlay[:WINDow]:TRACe:X[:<br />

SCALe]:ZOOM<br />

[:FREQuency]:STOP<br />

DISPlay[:WINDow]:TRACe:Y:<br />

SPACing<br />

FSE DISPlay[:WINDow]:TRACe:Y:<br />

SPACing<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]<br />

FSET/<br />

ESIB<br />

DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:BOTTom<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:MODE<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:PDIVision<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:RLEVel<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:RLEVel:OFFSet<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:RPOSition<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:RVALue<br />

FSE DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:RVALue:AUTO<br />

FSET/<br />

ESIB<br />

DISPlay[:WINDow]:TRACe:Y[:<br />

SCALe]:TOP<br />

LINear | LOGarithmic not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

LINear | LOGarithmic |<br />

LDB<br />

LINear | LOGarithmic |<br />

PERCent<br />

R&S <strong>FSQ</strong>:<br />

TRACe<br />

LDB is not available for<br />

FSE<br />

PERCent is not available<br />

for R&S <strong>FSQ</strong><br />

FSE: TRACE<br />

10dB to 200dB R&S <strong>FSQ</strong>:<br />

TRACe<br />

FSE: TRACE<br />

not available for<br />

R&S <strong>FSQ</strong><br />

ABSolute | RELative R&S <strong>FSQ</strong>:<br />

TRACe<br />

FSE: TRACE<br />

not available for<br />

R&S <strong>FSQ</strong><br />

-130dBm to 30dBm R&S <strong>FSQ</strong>:<br />

TRACe<br />

FSE: TRACE<br />

-200dB to 200dB R&S <strong>FSQ</strong>:<br />

TRACe<br />

FSE: TRACE<br />

0 to 100 PCT R&S <strong>FSQ</strong>:<br />

TRACe<br />

FSE: TRACE<br />

R&S <strong>FSQ</strong>:<br />

TRACe<br />

FSE: TRACE<br />

ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

Operating Manual 1313.9681.12 - 01 6.303