R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

CALCulate:MARKer:FUNCtion:SUMMary:PPEak[:STATe] ON | OFF<br />

CALCulate Subsystem<br />

This command switches on or off the measurement of the positive peak value in the selected<br />

measurement window.<br />

The function is independent of the marker selection, i.e. the numeric suffix of MARKer is<br />

irrelevant. It is only available in the time domain (span = 0).<br />

Example: "CALC:MARK:FUNC:SUMM:PPE ON"<br />

'Switches on the function in screen A.<br />

Characteristics: *RST value: OFF<br />

SCPI: device-specific<br />

Mode: A-T<br />

CALCulate:MARKer:FUNCtion:SUMMary:REFerence:AUTO ONCE<br />

With this command the currently measured average value (…:SUMMary:MEAN) and RMS value (…:<br />

SUMMary:RMS)are declared as reference values for relative measurements in the indicated<br />

measurement window. The function is independent of the marker selection, i.e. the numeric suffix<br />

of :MARKer is irrelevant. It is only available in the time domain (span = 0).<br />

If the measurement of RMS value and average is not activated, the reference value 0 dBm is used.<br />

If the function …:SUMMary:AVERage or …:SUMMary:PHOLd is switched on, the current value is the<br />

accumulated measurement value at the time considered.<br />

Example: "CALC:MARK:FUNC:SUMM:REF:AUTO ONCE"<br />

'Takes the currently measured power in screen A as reference value for the relative<br />

time domain power measurement.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A-T<br />

This command is an event and therefore has no *RST value and no query.<br />

CALCulate:MARKer:FUNCtion:SUMMary:RMS:AVERage:RESult?<br />

This command queries the result of the measurement of the averaged RMS value in the selected<br />

measurement window. The query is only possible if averaging has been activated previously using<br />

CALCulate:MARKer:FUNCtion:SUMMary:AVERage ON.<br />

The function is independent of the marker selection, i.e. the numeric suffix of :MARKer is<br />

irrelevant. It is only available in the time domain (span = 0).<br />

A complete sweep with synchronization to sweep end must be performed between switching on the<br />

function and querying the measured value to obtain a valid query result. This is only possible in singlesweep<br />

mode.<br />

Example: "INIT:CONT OFF"<br />

'Switches to single-sweep mode.<br />

"CALC:MARK:FUNC:SUMM:RMS ON"<br />

'Switches on the function in screen A.<br />

"CALC:MARK:FUNC:SUMM:AVER ON"<br />

Switches on the average value calculation in screen A.<br />

"INIT;*WAI"<br />

'Starts a sweep and waits for the end.<br />