R&S <strong>FSQ</strong> Instrument Functions<br />

4.8.1 External Generator Settings<br />

External Generator Control – Option R&S FSP-B10<br />

NETWORK The NETWORK hotkey opens the menu for setting the functions of the external generator.<br />

SOURCE<br />

POWER<br />

POWER<br />

OFFSET<br />

SOURCE POWER<br />

POWER OFFSET<br />

SOURCE CAL � CAL TRANS<br />

FREQUENCY OFFSET<br />

CAL REFL SHORT<br />

CAL REFL OPEN<br />

NORMALIZE<br />

REF VALUE POSITION<br />

REF VALUE<br />

RECALL<br />

SAVE AS TRD FACTOR<br />

EXT SOURCE � EXT SRC ON / OFF<br />

SELECT GENERATOR<br />

FREQUENCY SWEEP<br />

GEN REF INT / EXT<br />

Other softkeys are available in the displayed menus for controlling the internal<br />

tracking generator when option Tracking Generator R&S FSU-B9 is fitted. For<br />

detailed information see section “Tracking Generator – Option R&S FSU-B9” on<br />

page 4.221.<br />

The SOURCE POWER softkey activates the entry of the generator output level. The<br />

value range depends on the selected generator. For detailed information see “List of<br />

Generator Types Supported by the R&S <strong>FSQ</strong>” on page 4.248.<br />

If both option External Generator Control B10 and option Tracking Generator B9 are<br />

installed, the softkey will modify the output power of the generator currently in use.<br />

The default output power is -20 dBm.<br />

Remote command: SOUR:EXT:POW –20dBm<br />

The POWER OFFSET softkey activates the entry of a constant level offset of the<br />

generator. With this offset, attenuator pads or amplifiers connected to the output<br />

connector of the generator can be handled during the input and output of output levels.<br />

The permissible setting range is -200 dB to +200 dB in steps of 0.1 dB. Positive offsets<br />

handle a subsequent amplifier and negative offsets an attenuator pad.<br />

The default setting is 0 dB; offsets 0 are marked by the activated enhancement<br />

label LVL.<br />

Remote command: SOUR:POW:OFFS -10dB<br />

4.236 Operating Manual 1313.9681.12 - 01