R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

1) HP 8594E only<br />

2) Command will be accepted without error message, but will be ignored<br />

GPIB Commands of HP Models 856xE, 8566A/B, 8568A/B and 8594E<br />

Command Supported subset Function Corresponding<br />

HP-Models<br />

VB VB <br />

HZ|KHZ|MHZ|GHZ<br />

VB DN<br />

VB UP<br />

VB AUTO<br />

VB?<br />

VBR 1) VBR <br />

VBR DN<br />

VBR UP<br />

VBR?<br />

Video<br />

Bandwidth<br />

Video<br />

Bandwidth<br />

Ratio<br />

HP 856xE /<br />

HP 8566B /<br />

HP 8568B /<br />

HP 8594E<br />

HP 856xE /<br />

HP 8566B /<br />

HP 8568B /<br />

HP 8594E<br />

VIEW VIEW TRA|TRB|TRC HP 856xE /<br />

HP 8566B /<br />

HP 8568B /<br />

HP 8594E<br />

VTL VTL DB|DM<br />

VTL DN<br />

VTL UP<br />

VTL?<br />

Video Trigger<br />

Level<br />

HP 856xE /<br />

HP 8594E<br />

6.23.3 Special Features of the Syntax Parsing Algorithms for 8566A and<br />

8568A Models<br />

The command syntax is very different for models A and B. Different names are assigned to identical<br />

instrument functions, and the command structure likewise differs considerably between models A and<br />

models B.<br />

The command structure for models A is as follows:<br />

::=<br />

[][|][][][]...<br />

::= [][][][][][]...<br />

::= UP|DN<br />

where<br />

= see Table "Supported Commands"<br />

= integer or floating-point numerical value<br />

= DM | -DM | DB | HZ | KZ | MZ | GZ | MV | UV | SC | MS | US<br />

= | | | | <br />

= 3210<br />

Status<br />

available<br />

available<br />

available<br />

available in V3.3x and above<br />

= 310<br />

Command sections given in [ ] are optional.<br />

The R&S <strong>FSQ</strong> GPIB hardware differs from that used in the HP analyzers. Therefore, the following constraint<br />

exists:<br />

| are still used as delimiters since the GPIB hardware is able to identify them. The other<br />

delimiters are identified and evaluated during syntax analysis.<br />

6.274 Operating Manual 1313.9681.12 - 01