R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Differences in GPIB Behavior between the FSP and the FSE Families of Instruments<br />

Devices Command (Sheet 30 of 47) Parameter Notes<br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

FSE [SENSe:]AVERage:AUTO ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]AVERage:COUNt 0 to 32767<br />

FSE [SENSe:]AVERage:COUNt 0 to 32767<br />

[SENSe:]AVERage:TYPE VIDeo | LINear command is used to<br />

select logarithmic or<br />

linear averaging on the<br />

R&S <strong>FSQ</strong>;<br />

therefore parameters are<br />

incompatible to the FSE<br />

FSE [SENSe:]AVERage:TYPE MAXimum | MINimum |<br />

SCALar<br />

FSE [SENSe:]AVERage[:STATe] ON | OFF<br />

command is used to<br />

select logarithmic or<br />

linear averaging on the<br />

R&S <strong>FSQ</strong>;<br />

therefore parameters are<br />

incompatible to the FSE<br />

FSE [SENSe:]BANDwidth|BWIDth:DEMod not available for<br />

R&S <strong>FSQ</strong> and FSET<br />

FSE [SENSe:]BANDwidth|BWIDth:PLL AUTO | HIGH | MEDium<br />

| LOW<br />

FSE [SENSe:]BANDwidth|BWIDth:VIDeo 1Hz to 10MHz<br />

FSET [SENSe:]BANDwidth|BWIDth:VIDeo 1Hz to 500MHz<br />

FSE [SENSe:]BANDwidth|BWIDth:VIDeo:AUTO ON | OFF<br />

FSET [SENSe:]BANDwidth|BWIDth:VIDeo:<br />

EXTernal[:STATe]<br />

ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

[SENSe:]BANDwidth|BWIDth:VIDeo:RATio 0.0001 to 1 only numeric values<br />

available. Parameter<br />

ranges differ between<br />

R&S <strong>FSQ</strong> and FSE<br />

FSE [SENSe:]BANDwidth|BWIDth:VIDeo:RATio 0.001 to 1000 | SINe |<br />

PULSe | NOISe<br />

FSE [SENSe:]BANDwidth|BWIDth[:RESolution] 10Hz to 10MHz (anal.<br />

filter) 1Hz to 10MHz<br />

(FFT filter)<br />

FSET [SENSe:]BANDwidth|BWIDth[:RESolution] 10 Hz to 500MHz<br />

FSE [SENSe:]BANDwidth|BWIDth[:RESolution]:<br />

AUTO<br />

FSE [SENSe:]BANDwidth|BWIDth[:RESolution]:<br />

MODE<br />

ON | OFF<br />

also text parameters are<br />

available. Parameter<br />

ranges differ between<br />

R&S <strong>FSQ</strong> and FSE<br />

not available for FSET<br />

FSE: 10Hz to 10MHz<br />

(models 20) 1Hz to<br />

10MHz (models 30)<br />

ANALog | DIGital not available for<br />

R&S <strong>FSQ</strong> and FSET<br />

6.312 Operating Manual 1313.9681.12 - 01