R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

CALCulate:MARKer:FUNCtion:REFerence<br />

CALCulate Subsystem<br />

This command sets the reference level to the power measured by the indicated marker. If the selected<br />

marker was used as delta marker, it is switched to marker mode.<br />

Example: "CALC:MARK2:FUNC:REF"<br />

'Sets the reference level of screen A to the level of marker 2.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

This command is an event and therefore has no *RST value and no query.<br />

CALCulate:MARKer:FUNCtion:TOI:MARKer CALCulate | SEARch<br />

This command controls the positioning of the intercept markers 3 and 4 for TOI measurement, based<br />

on the two carrier signals.<br />

• CALCulate:<br />

Calculates the intermodulation product frequencies.<br />

• SEARch:<br />

Performs a local peak search near the expected intermodulation product frequencies.<br />

Example: "CALC:MARK:FUNC:TOI:MARK SEAR"<br />

' selects TOI marker search mode<br />

Characteristics: *RST value: CALC<br />

SCPI: device-specific<br />

Mode: A<br />

CALCulate:MARKer:FUNCtion:TOI:RESult?<br />

This command queries the third-order intercept point measurement in the indicated measurement<br />

window.<br />

A complete sweep with synchronization to sweep end must be performed between switching on the<br />

function and querying the measured value to obtain a valid query result. This is only possible in singlesweep<br />

mode.<br />

The numeric suffix of :MARKer is irrelevant of this command.<br />

Example: "INIT:CONT OFF"<br />

'Switches to single-sweep mode.<br />

"CALC:MARK:FUNC:TOI ON"<br />

'Switches the intercept measurement in screen A.<br />

"INIT;*WAI"<br />

'Starts a sweep and waits for the end.<br />

"CALC:MARK:FUNC:TOI:RES?"<br />

'Outputs the measured value of screen A.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

This command is only a query and therefore has no *RST value.<br />