R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

"INIT;*WAI"<br />

'Starts a new measurement and waits for the sweep end.<br />

"CALC:LIM:ACP:ACH:RES?"<br />

'Queries the limit check result in the adjacent channels in screen A.<br />

Characteristics: *RST value: OFF<br />

SCPI: device-specific<br />

Mode: A<br />

CALCulate:LIMit:ACPower:ACHannel[:RELative] 0 to 100dB, 0 to 100dB<br />

CALCulate Subsystem<br />

This command defines the relative limit of the upper/lower adjacent channel for adjacent channel<br />

power measurements in the selected measurement window. The reference value for the relative limit<br />

value is the measured channel power.<br />

It should be noted that the relative limit value has no effect on the limit check as soon as it is below the<br />

absolute limit value defined with CALCulate:LIMit:ACPower:ACHannel:ABSolute. This<br />

mechanism allows automatic checking of the absolute basic values of adjacent channel power as<br />

defined in mobile radio standards.<br />

The numeric suffixes are irrelevant for this command.<br />

Parameter: The first numeric value is the limit for the upper (lower) adjacent channel. The<br />

second value is ignored but must be indicated for reasons of compatibility with the<br />

FSE family.<br />

Example: "CALC:LIM:ACP:ACH 30DB, 30DB"<br />

'Sets the relative limit value in screen A for the power in the lower and upper<br />

adjacent channel to 30 dB below the channel power.<br />

Characteristics: *RST value: 0 dB<br />

SCPI: device-specific<br />

Mode: A<br />

CALCulate:LIMit:ACPower:ACHannel[:RELative]:STATe ON | OFF<br />

This command activates the limit check for the relative limit value of the adjacent channel when<br />

adjacent channel power measurement is performed. Before the command, the limit check must be<br />

activated using CALCulate:LIMit:ACPower:STATe ON.<br />

The result can be queried with CALCulate:LIMit:ACPower:ACHannel:RESult?. It should be<br />

noted that a complete measurement must be performed between switching on the limit check and the<br />

result query, since otherwise no valid results are available.<br />

The numeric suffixes are irrelevant for this command.<br />

Example: "CALC:LIM:ACP:ACH 30DB, 30DB"<br />

'Sets the relative limit value in screen A for the power in the lower and upper<br />

adjacent channel to 30 dB below the channel power.<br />

"CALC:LIM:ACP:ACH:ABS -35DBM, -35DBM"<br />

'Sets the absolute limit value in screen A for the power in the lower and upper<br />

adjacent channel to -35 dBm.<br />

"CALC:LIM:ACP ON"<br />

'Switches on globally the limit check for the channel/adjacent channel<br />

measurement in screen A.<br />

Operating Manual 1313.9681.12 - 01 6.31