R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Differences in GPIB Behavior between the FSP and the FSE Families of Instruments<br />

Devices Command (Sheet 32 of 47) Parameter Notes<br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TRANsducer:ACTive?<br />

FSE [SENSe:]CORRection:TRANsducer:<br />

CATalog?<br />

FSE [SENSe:]CORRection:TRANsducer:<br />

COMMent<br />

<br />

FSE [SENSe:]CORRection:TRANsducer:DATA , to<br />

FSE [SENSe:]CORRection:TRANsducer:DELete<br />

FSE [SENSe:]CORRection:TRANsducer:<br />

SCALing<br />

FSE [SENSe:]CORRection:TRANsducer:SELect <br />

FSE [SENSe:]CORRection:TRANsducer:UNIT <br />

FSE [SENSe:]CORRection:TRANsducer[:STATe] ON | OFF<br />

LINear|LOGarithmic<br />

FSE [SENSe:]CORRection:TSET:ACTive? not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:BREak ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:CATalog? not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:COMMent not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:DELete not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:<br />

RANGe<br />

,,<br />

to<br />

not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:SELect not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET:UNIT not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:TSET[:STATe] ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]CORRection:YIG:TEMPerature:<br />

AUTO<br />

ON | OFF new function for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]DDEMod:FILTer:ALPHa 0.2 to 1 not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]DDEMod:FILTer:MEASurement OFF | RCOSine |<br />

RRCosine | GAUSsian |<br />

B22 | B25 | B44 | QFM |<br />

QFR | QRM | QRR |<br />

A25Fm | EMES | EREF<br />

not available for<br />

R&S <strong>FSQ</strong><br />

6.314 Operating Manual 1313.9681.12 - 01