R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

[SENSe:]SWEep:EGATe:SOURce EXTernal | IFPower<br />

SENSe Subsystem<br />

This command toggles between external gate signal and IF power signal as a signal source for the<br />

gate mode. If an IF power signal is used, the gate is opened as soon as a signal at > -20 dBm is<br />

detected within the IF path bandwidth (50 MHz).<br />

Example: "SWE:EGAT:SOUR IFP"<br />

'Switches the gate source to IF power.<br />

Characteristics: *RST value: IFPower<br />

SCPI: device-specific<br />

Mode: A<br />

[SENSe:]SWEep:EGATe:TRACeCOMMent<br />

To enter a comment string in the gate range table.<br />

The suffix after TRACe indicates the trace.<br />

Example: "SWE:EGAT:TRAC2:COMMent"<br />

’To enter a comment in trace 2.<br />

Characteristics: *RST value: --<br />

SCPI: device-specific<br />

Mode: A<br />

[SENSe:]SWEep:EGATe:TRACePERiod <br />

The period of the signal is set for the gate range table.<br />

The suffix after TRACe indicates the trace.<br />

Example: "SWE:EGAT:TRAC1:PER 5ms"<br />

’Period of trace 1 is set to 5 ms.<br />

Characteristics: *RST value: 1.797693135E+308<br />

SCPI: device-specific<br />

Mode: A<br />

[SENSe:]SWEep:EGATe:TRACeSTARt | STOP <br />

Sets the start or stop value of a gate range in the gate range table.<br />

The suffix after TRACe indicates the trace.<br />

The suffix after STARt | STOP indicates the range.<br />

Example: "SWE:EGAT:TRAC1:STAR2 5us"<br />

’Start value of range 2, trace 1 is set to 5 µs.<br />

Characteristics: *RST value: 1.797693135E+308<br />

SCPI: device-specific<br />

Mode: A<br />

[SENSe:]SWEep:EGATe:TRACeSTATe ON | OFF<br />

The gate range in the gate range table is set on or off.<br />

The suffix after TRACe indicates the trace.<br />

The suffix after STATe indicates the range.<br />