R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

GPIB Commands of HP Models 856xE, 8566A/B, 8568A/B and 8594E<br />

6.23 GPIB Commands of HP Models 856xE, 8566A/B,<br />

8568A/B and 8594E<br />

6.23.1 Introduction<br />

The R&S FSP analyzer family supports a subset of the GPIB commands of HP models 8560E, 8561E,<br />

8562E, 8563E, 8564E, 8565E, 8566A, 8566B, 8568A, 8568B and 8594E.<br />

Despite the differences in system architecture and device features, the supported commands have been<br />

implemented in a way to ensure a sufficiently high degree of correspondence with the original.<br />

This includes the support of syntax rules for not only newer device families (B and E models) but for the<br />

previous A family as well.<br />

In many cases the selection of commands supported by the R&S <strong>FSQ</strong> is sufficient to run an existing<br />

GPIB program without adaptation.<br />

The device model to be emulated is selected manually by means of the key sequence SETUP - GEN-<br />

ERAL SETUP - GPIB - GPIB LANGUAGE via the GPIB using the SYSTem:LANGuage command.<br />

To make it possible to also emulate device models that are not part of the selection list of the GPIB LAN-<br />

GUAGE softkey, the identification string received in response to the ID command can be modified (key<br />

sequence SETUP - GENERAL SETUP - GPIB - ID STRING USER). This allows any device model to be<br />

emulated whose command set is compatible with one of the supported device models.<br />

6.23.2 Command Set of Models 8560E, 8561E, 8562E, 8563E, 8564E,<br />

8565E, 8566A/B, 8568A/B, 8591E, 8594E, 71100C, 71200C, and<br />

71209A<br />

As with the original units, the R&S <strong>FSQ</strong> includes the command set of the A models in the command set<br />

of the B models.<br />

The HP model 8591E is compatible to HP model 8594E, the HP models 71100C,<br />

71200C, and 71209A are compatible to HP models 8566A/B.<br />

Command Supported subset Function Corresponding<br />

HP-Models<br />

A1 A1 Clear/Write A HP 8566A/<br />

HP 8568A<br />

A2 A2 Max Hold A HP 8566A/<br />

HP 8568A<br />

A3 A3 View A HP 8566A/<br />

HP 8568A<br />

A4 A4 Blank A HP 8566A/<br />

HP 8568A<br />

ABORT 1) ABORT Stop previous<br />

function<br />

HP 856xE /<br />

HP 8566B /<br />

HP 8568B /<br />

HP 8594E<br />

ADD Add HP 8566B /<br />

HP 8568B /<br />

HP 8594E<br />

Status<br />

available<br />

available<br />

available<br />

available<br />

available<br />

available in V4.1x and above<br />

6.256 Operating Manual 1313.9681.12 - 01