R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

CALCulate:MARKer:FUNCtion:SUMMary:MEAN:RESult?<br />

CALCulate Subsystem<br />

This command queries the result of the measurement of the mean value in the selected measurement<br />

window.<br />

The function is independent of the marker selection, i.e. the numeric suffix of :MARKer is<br />

irrelevant. It is only available in the time domain (span = 0).<br />

A complete sweep with synchronization to sweep end must be performed between switching on the<br />

function and querying the measured value to obtain a valid query result. This is only possible in singlesweep<br />

mode.<br />

Example: "INIT:CONT OFF"<br />

'Switches to single-sweep mode.<br />

"CALC:MARK:FUNC:SUMM:MEAN ON"<br />

'Switches on the function in screen A.<br />

"INIT;*WAI"<br />

'Starts a sweep and waits for the end.<br />

"CALC:MARK:FUNC:SUMM:MEAN:RES?"<br />

'Outputs the result of screen A.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A-T<br />

This command is only a query and therefore has no *RST value.<br />

CALCulate:MARKer:FUNCtion:SUMMary:MEAN[:STATe] ON | OFF<br />

This command switches on or off the measurement of the mean value in the selected measurement<br />

window.<br />

The function is independent of the marker selection, i.e. the numeric suffix of :MARKer is<br />

irrelevant. It is only available in the time domain (span = 0).<br />

Example: "CALC:MARK:FUNC:SUMM:MEAN ON"<br />

'Switches on the function in screen A.<br />

Characteristics: *RST value: OFF<br />

SCPI: device-specific<br />

Mode: A-T<br />

The measurement is performed on the trace on which marker 1 is positioned. In<br />

order to evaluate another trace, marker 1 must be positioned on another trace with<br />

CALC:MARK:TRAC 1|2|3.<br />

CALCulate:MARKer:FUNCtion:SUMMary:MODE ABSolute | RELative<br />

This command selects absolute or relative time domain power measurement in the indicated<br />

measurement window. The function is independent of the marker selection, i.e. the numeric suffix<br />

of :MARKer is irrelevant. It is only available in the time domain (span = 0).<br />

The reference power for relative measurement is defined with CALCulate:MARKer:FUNCtion:<br />

SUMMary:REFerence:AUTO ONCE. If the reference power is not defined, the value 0 dBm is used.<br />

Operating Manual 1313.9681.12 - 01 6.83