R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

DISPlay[:WINDow]:TRACe:Y[:SCALe]:RLEVel:OFFSet -200dB to 200dB<br />

DISPlay Subsystem<br />

This command defines the offset of the reference level in the selected measurement window.<br />

Depending on the coupling of the measurement windows, it is valid for both screens or only for the<br />

selected measurement window (INSTrument:COUPle).<br />

The numeric suffix at TRACe is irrelevant.<br />

Example: "DISP:TRAC:Y:RLEV:OFFS -10dB"<br />

Characteristics: *RST value: 0dB<br />

SCPI: conform<br />

Mode: A<br />

DISPlay[:WINDow]:TRACe:Y[:SCALe]:RPOSition 0 to 100PCT<br />

This command defines the position of the reference value in the selected measurement window. The<br />

numeric suffix in TRACe is irrelevant.<br />

In NETWORK mode (Tracking Generator/Ext. Generator Option R&S FSU-B9/R&S FSP-B10) with<br />

active normalization, RPOSition defines the reference point for the output of the normalized<br />

measurement results.<br />

Example: "DISP:TRAC:Y:RPOS 50PCT"<br />

Characteristics: *RST value:<br />

100PCT(analyzer mode)<br />

50 PCT (NETWORK mode)<br />

Characteristics: SCPI: conform<br />

Mode: A<br />

DISPlay[:WINDow]:TRACe:Y[:SCALe]:RVALue <br />

If the tracking generator option or the external generator control option (R&S FSU-B9/R&S FSP-B10)<br />

is available and the normalization in the NETWORK mode is activated, this value defines the power<br />

value assigned to the reference position in the selected measurement window. This value corresponds<br />

to the parameter REFERENCE VALUE in manual operation.<br />

The numeric suffix at TRACe is irrelevant.<br />

Example: "DISP:TRAC:Y:RVAL 0"<br />

'Sets the power value assigned to the reference position to 0 dB (Tracking<br />

Generator/Ext. Generator Control option).<br />

Characteristics: *RST value:<br />

0 dB (NETWORK mode)<br />

Mode: A<br />

DISPlay[:WINDow]:TRACe:Y:SPACing LINear | LOGarithmic | LDB<br />

This command toggles between linear and logarithmic display in the selected measurement window.<br />

On a linear scale, switch over between the unit % (command DISP:WIND:TRAC:Y:SPAC LIN) and<br />

the unit dB (command DISP:WIND:TRAC:Y:SPAC LDB) is also possible.<br />

If the FM demodulator (R&S FS-K7) is active and result display AF spectrum of FM, AM or PM is<br />

selected, only the parameters LINear and LOGarithmic are permissible.<br />

The numeric suffix in TRACe is irrelevant.<br />

Operating Manual 1313.9681.12 - 01 6.113