18.12.2012 Views

R&S FSQ Signal Analyzer - Rohde & Schwarz

R&S FSQ Signal Analyzer - Rohde & Schwarz

R&S FSQ Signal Analyzer - Rohde & Schwarz

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

6.16.6 SENSe:FM Subsystem<br />

SENSe Subsystem<br />

The SENSe:FM subsystem controls the FM demodulation. The measurement windows are selected by<br />

SENSe1 (screen A) and SENSe2 (screen B).<br />

[SENSe:]FM ON | OFF<br />

This command switches FM demodulation on or off.<br />

Example: "FM ON"<br />

Characteristics: *RST value: OFF<br />

SCPI: device-specific<br />

Mode: A<br />

[SENSe:]FM[:DEViation]:RANGe:AUTO ON | OFF<br />

This command links the FM demodulation span to the selected resolution bandwidth.<br />

Example: "FM:RANG:AUTO OFF"<br />

Characteristics: *RST value: ON<br />

SCPI: conform<br />

Mode: A<br />

[SENSe:]FM[:DEViation]:RANGe[:UPPer] <br />

This command selects the FM demodulation span.<br />

Example: "FM:RANG 300kHZ"<br />

Characteristics: *RST value: -<br />

SCPI: conform<br />

Mode: A<br />

[SENSe:]FM:FILTer:HPASs:FREQuency 0 Hz | 10 Hz | 100 Hz | 1 kHz<br />

This command selects the AF highpass filters for disconnecting the DC component.<br />

Example: "FM:FILT:HPAS:FREQ 100"<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

[SENSe:]FM:FILTer[:LPASs]:AUTO ON | OFF<br />

This command links the AF lowpass filters to the resolution bandwidth or deactivates coupling.<br />

Example: "FM:FILT:AUTO OFF"<br />

Characteristics: *RST value: ON<br />

SCPI: device-specific<br />

Mode: A<br />