R&S <strong>FSQ</strong> Instrument Functions<br />

SIGNAL<br />

STATISTIC<br />

<strong>Analyzer</strong> Mode<br />

The SIGNAL STATISTIC softkey opens a submenu for measurement of signal<br />

statistics.<br />

APD (ON OFF)<br />

CCDF (ON OFF)<br />

PERCENT MARKER<br />

RES BW<br />

NO OF SAMPLES<br />

SCALING � X-AXIS REF LEVEL<br />

ADJUST SETTINGS<br />

CONT MEAS<br />

SINGLE MEAS<br />

Side menu<br />

GATED TRIGGER<br />

GATE RANGES<br />

X-AXIS RANGE<br />

Y-UNIT (% ABS)<br />

Y-AXIS MAX VALUE<br />

Y-AXIS MIN VALUE<br />

ADJUST SETTINGS<br />

DEFAULT SETTINGS<br />

MEAN PWR POSITION<br />

In the submenu measurement of amplitude probability density (APD) and complementary<br />

cumulative distribution (CCDF) can be selected alternately. Only one of the<br />

signal statistic functions can be switched on at a time.<br />

In default mode all statistic functions are switched off.<br />

With a statistic function switched on the R&S <strong>FSQ</strong> is set into zero span mode automatically.<br />

The R&S <strong>FSQ</strong> measures the statistics of the signal applied to the RF input with the<br />

resolution bandwidth set. In order not to influence the peak amplitudes the video<br />

bandwidth is automatically set to 10 times the resolution bandwidth. The sample<br />

detector is used for detecting the video voltage.<br />

APD (ON OFF) The APD (ON OFF) softkey switches on or off the amplitude probability distribution<br />

function. When the APD function is switched on, the CCDF function is switched off<br />

automatically.<br />

Remote command: CALC:STAT:APD ON<br />

CCDF (ON OFF) The CCDF (ON OFF) softkey switches on or off the complementary cumulative distribution<br />

function. When the CCDF function is switched on, the APD function is<br />

switched off automatically.<br />

Remote command: CALC:STAT:CCDF ON<br />

Operating Manual 1313.9681.12 - 01 4.111