R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Differences in GPIB Behavior between the FSP and the FSE Families of Instruments<br />

Devices Command (Sheet 14 of 47) Parameter Notes<br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

CALCulate:MATH:MODE LINear | LOGarithmic affects all traces on the<br />

R&S <strong>FSQ</strong>; therefore the<br />

numeric suffix :<br />

MATH is not<br />

allowed for the<br />

R&S <strong>FSQ</strong><br />

FSE CALCulate:MATH:MODE LINear | LOGarithmic for FSE, only the trace<br />

indicated by a numeric<br />

suffix is affected<br />

CALCulate:MATH:POS -100PCT to 200PCT new function for<br />

R&S <strong>FSQ</strong>; replacement<br />

for CALC:RLINe of the<br />

FSE<br />

FSE CALCulate:MATH:STATe ON | OFF for R&S <strong>FSQ</strong>, traces<br />

can only be subtracted<br />

from trace 1; therefore<br />

there is no numeric suffix<br />

behind :MATH<br />

FSE CALCulate:MATH[:EXPRession][:DEFine] for R&S <strong>FSQ</strong>, traces<br />

can only be subtracted<br />

from trace 1; therefore<br />

there is no numeric suffix<br />

behind :MATH and<br />

may only consist<br />

of (TRACE1-TRACE2)<br />

or (TRACE1-TRACE3)<br />

FSE CALCulate:RLINe MIN to MAX not available for<br />

R&S <strong>FSQ</strong> (replaced by<br />

CALC:MATH:POS)<br />

FSE CALCulate:RLINe:STATe ON | OFF not available for<br />

R&S <strong>FSQ</strong> (replaced by<br />

CALC:MATH:POS)<br />

FSE CALCulate:THReshold MIN to MAX<br />

FSE CALCulate:THReshold:STATe ON | OFF<br />

FSE CALCulate:TLINe 0 to 1000s not available on the<br />

R&S <strong>FSQ</strong>; replaced by<br />

CALC:SLIMits:LEFT and<br />

CALC:SLIMits:RIGHt<br />

FSE CALCulate:TLINe:STATe ON | OFF not available on the<br />

R&S <strong>FSQ</strong>; replaced by<br />

CALC:SLIMits:LEFT and<br />

CALC:SLIMits:RIGHt<br />

FSE CALCulate:UNIT:ANGLe DEG | RAD not available for<br />

R&S <strong>FSQ</strong><br />

CALCulate:UNIT:POWer DBM | V | A | W | DBPW<br />

| WATT | DBUV | DBMV<br />

| VOLT | DBUA |<br />

AMPere<br />

available units are<br />

compatible to the FSE<br />

6.296 Operating Manual 1313.9681.12 - 01