R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Differences in GPIB Behavior between the FSP and the FSE Families of Instruments<br />

Devices Command (Sheet 26 of 47) Parameter Notes<br />

FSET INPut:PRESelection:COUPling:LOW:<br />

FREQuency<br />

10Hz to 5MHz not available for<br />

R&S <strong>FSQ</strong><br />

FSET INPut:PRESelection:COUPling:LOW:SET 'name of preselector set<br />

for low RBW'<br />

FSET INPut:PRESelection:COUPling:MID:SET 'name of preselector set<br />

for medium RBW'<br />

FSET INPut:PRESelection:FILTer:HPASS[:<br />

FREQuency]<br />

FSET INPut:PRESelection:FILTer:LPASS[:<br />

FREQuency]<br />

not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

100Hz to 5MHz not available for<br />

R&S <strong>FSQ</strong><br />

20KHz to 40MHz not available for<br />

R&S <strong>FSQ</strong><br />

FSET INPut:PRESelection:FILTer[:STATe] ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

FSET INPut:PRESelection:SET NARRow | NORMal |<br />

WIDE<br />

FSET INPut:PRESelection:USET[:SELect] 'name of user defined<br />

preselector set'<br />

not available for<br />

R&S <strong>FSQ</strong><br />

not available for<br />

R&S <strong>FSQ</strong><br />

FSET INPut:PRESelection[:STATe] ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

FSET INPut:TYPE RF | BALanced not available for<br />

R&S <strong>FSQ</strong><br />

ESIB INPut:TYPE INPUT1 | INPUT2 not available for<br />

R&S <strong>FSQ</strong><br />

FSE INPut:UPORt:STATe ON | OFF not available for<br />

R&S <strong>FSQ</strong><br />

FSE INPut:UPORt[:VALue]? not available for<br />

R&S <strong>FSQ</strong><br />

ESIB INPut2:COUPling AC | DC not available for<br />

R&S <strong>FSQ</strong><br />

INSTrument:COUPle NONE | RLEVel | CF_B |<br />

CF_A<br />

FSE INSTrument:COUPle NONE | MODE | X | Y |<br />

CONTrol | XY |<br />

XCONtrol | YCONtrol |<br />

ALL<br />

available coupling<br />

modes between Screen<br />

A and Screen B have<br />

been changed between<br />

FSE and R&S <strong>FSQ</strong><br />

Available coupling<br />

modes between screen<br />

A and screen B have<br />

been changed between<br />

FSE and R&S <strong>FSQ</strong><br />

INSTrument:NSELect 1 currently only parameter<br />

value 1 available<br />

ESIB INSTrument:NSELect 1 to 3 | 6 4 parameter values are<br />

available<br />

FSE/<br />

FSIQ<br />

INSTrument:NSELect 1 to 5 5 parameter values are<br />

available<br />

FSET INSTrument:NSELect 1 | 2 | 6 3 parameter values are<br />

available<br />

INSTrument[:SELect] SANalyzer Currently only<br />

SANalyzer available<br />