R&S <strong>FSQ</strong> Instrument Functions<br />

Example - data section of the file<br />

File contents Description<br />

Trace 1:;; Selected trace<br />

x-Unit;Hz; Unit of x values:<br />

Hz with span > 0; s with span = 0;<br />

dBm/dB with statistics measurements<br />

<strong>Analyzer</strong> Mode<br />

y-Unit;dBm; Unit of y values:<br />

dB*/V/A/Ω depending on the selected unit with y axis LOG or % with<br />

y-axis LIN<br />

Preamplifier;OFF; Preamplifier state (OFF, if no preamplifier is available)<br />

Transducer;OFF; Transducer state:<br />

OFF:No transducer active (or available)<br />

selected transducer<br />

Values; 625; Number of measurement points<br />

10000;-10.3;-15.7<br />

10180;-11.5;-16.9<br />

10360;-12.0;-17.4<br />

...;...;<br />

DECIM SEP The DECIM SEP softkey selects the decimal separator between '.' (decimal point)<br />

and ',' (comma) with floating-point numerals for the ASCII FILE EXPORT function.<br />

With the selection of the decimal separator different language versions of evaluation<br />

programs (e.g. Microsoft Excel) can be supported.<br />

Remote command: FORM:DEXP:DSEP POIN<br />

Measured values:<br />

, , <br />

being available only with detector AUTOPEAK and containing<br />

in this case the smallest of the two measured values for a test point.<br />

COPY TRACE The COPY TRACE softkey copies the screen contents of the current trace into<br />

another trace memory. The desired memory is selected by entering the number 1, 2<br />

or 3.<br />

Upon copying, the contents of the selected memory is overwritten and the new contents<br />

displayed in view mode.<br />

Remote command: TRAC:COPY TRACE1,TRACE2<br />

4.5.8.1 Selection of Detector<br />

The detectors of the R&S <strong>FSQ</strong> are implemented as pure digital devices. The<br />

following detectors are available:<br />

• “Peak detectors (MAX PEAK and MIN PEAK)” on page 4.48<br />

• “Auto peak detector” on page 4.48<br />

• “Sample detector” on page 4.48<br />

• “RMS detector” on page 4.48<br />

• “Average detector” on page 4.49<br />

• “Quasipeak detector” on page 4.49<br />

Operating Manual 1313.9681.12 - 01 4.47