R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

WIBro WiMAX WiBro (Wireless Broadband) IEEE 802.16-2004/Cor1-2005<br />

Example: "CALC:MARK:FUNC:POW:PRES BWLan"<br />

Selects the standard setting for WLAN 802.11b.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A-F<br />

CALCulate:MARKer:FUNCtion:POWer:RESult:PHZ ON | OFF<br />

CALCulate Subsystem<br />

EUTRa E-UTRA/LTE Square<br />

Use this standard setting to measure the assumed adjacent channel carrier configuration, E-UTRA of<br />

same BW. In this mode, on all channels a square filter is applied.<br />

REUTra E-UTRA/LTE Square/RRC<br />

Use this standard setting to measure the assumed adjacent channel carrier configuration, 1.28, 3.84, 7.68,<br />

Mcps UTRA. In this mode, a square filter is applied to the Tx channel and a RRC filter is applied to the<br />

adjacent, alternate channels.<br />

is the file name of a customized standard that has been saved with SAVE AS USER STD.<br />

The settings for standards IS95A and C differ as far as the calculation method of<br />

channel spacings is concerned. For IS95A and J-STD008 the spacing is calculated<br />

from the center of the main channel to the center of the corresponding adjacent<br />

channel, for IS95C from the center of the main channel to the nearest border<br />

of the adjacent channel.<br />

This command switches the query response of the power measurement results in the indicated<br />

measurement window between output of absolute values (OFF) and output referred to the<br />

measurement bandwidth (ON).<br />

The measurement results are output with CALCulate:MARKer:FUNCtion:POWer:RESult?<br />

Parameter: ON: Results output referred to measurement bandwidth.<br />

OFF: Results output in absolute values.<br />

Example of channel/adjacent channel measurement:<br />

"SENS2:POW:ACH:ACP 3" 'Sets the number of adjacent channels in screen B to 3.<br />

"SENS2:POW:ACH:BAND 30KHZ" 'Sets the bandwidth of the main channel to 30 kHz.<br />

"SENS2:POW:ACH:BAND:ACH 40KHZ" 'Sets the bandwidth of all adjacent channels to 40 kHz.<br />

"SENS2:POW:ACH:BAND:ALT1 50KHZ" 'Sets the bandwidth of all alternate adjacent channels to<br />

50 kHz.<br />

"SENS2:POW:ACH:BAND:ALT2 60KHZ" 'Sets the bandwidth of alternate adjacent channel 2 to<br />

60 kHz.<br />

"SENS2:POW:ACH:SPAC 30KHZ" 'Sets the spacing between channel and adjacent channel<br />

as well as between all adjacent channels to 30 kHz.<br />

"SENS2:POW:ACH:SPAC:ALT1 40KHZ" 'Sets the spacing between adjacent channel and alternate<br />

adjacent channel as well as between all alternate<br />

adjacent channels to 40 kHz.<br />

"SENS2:POW:ACH:SPAC:ALT2 50KHZ" 'Sets the spacing between alternate adjacent channel 1<br />

and alternate adjacent channel 2 to 50 kHz.<br />

"SENS2:POW:ACH:MODE ABS" 'Switches on absolute power measurement.<br />