R&S <strong>FSQ</strong> Instrument Functions<br />

FREQUENCY<br />

SWEEP<br />

Generator Interface<br />

Type<br />

1) The upper frequency limit depends on the frequency option the generator is fitted with.<br />

External Generator Control – Option R&S FSP-B10<br />

SMT02 GPIB 5.0 kHz 1.5 GHz -144 +13<br />

SMT03 GPIB 5.0 kHz 3.0 GHz -144 +13<br />

SMT06 GPIB 5.0 kHz 6.0 GHz -144 +13<br />

SMV03 GPIB 9 kHz 3.3 GHz -140 +13<br />

SMU200A 3) TTL 100 kHz 6 GHz -145 +19<br />

SMX GPIB 100 kHz 1.0 GHz -137 +13<br />

SMY01 GPIB 9 kHz 1.04 GHz -140 +13<br />

SMY02 GPIB 9 kHz 2.08 GHz -140 +13<br />

HP8254A GPIB 250 kHz 4 GHz -135 +25<br />

HP8257D GPIB 250 kHz 7 GHz -135 +25<br />

HP8340A GPIB 10 MHz 26.5 GHz -110 10<br />

HP8648 GPIB 9 kHz 4 GHz -136 10<br />

HP ESG-A<br />

Series 1000A,<br />

2000A,<br />

3000A,<br />

4000A<br />

HP ESG-D<br />

SERIES<br />

E4432B<br />

Generator<br />

Min Freq<br />

Generator<br />

Max Freq<br />

GPIB 250 kHz 4 GHz -136 20<br />

GPIB 250 kHz 3 GHz -136 +10<br />

In the dialog box that selects the generator, the upper frequency is indicated by the extension of the generator type (e.g. generator type<br />

SMBV100A6 means an SMBV100A with an upper frequency of 6 GHz).<br />

The respective frequency is indicated by the name of the generator as shown by the dialog on the R&S <strong>FSQ</strong>, e.g. the SMBV100A6 means an<br />

upper frequency limit of 6 GHz.<br />

2) The upper frequency limit, minimum and maximum power depends on the model of the R&S SMR. In addition, the minimum and maximum<br />

power depends on whether options R&S SMR-B15/-B17 is installed or not. The lower frequency limit depends on whether option<br />

R&S SMR-B11 is installed or not.<br />

Refer to the data sheet of the R&S SMR for more information.<br />

3) The upper frequency limit, minimum and maximum power depend on which RF Path option R&S SMU-B10x is installed and on whether<br />

option R&S SMU-B31 is installed or not.<br />

Refer to the data sheet of the R&S SMU for more information.<br />

The FREQUENCY SWEEP softkey opens a table for setting the generator level as<br />

well as the multiplier and the offset used to derive the generator frequency from the<br />

analyzer frequency.<br />

This table also permits configuration of two generators so that switching between<br />

two different configurations is easily possible.<br />

The individual fields contain the following settings:<br />

Generator<br />

Min Power<br />

dBm<br />

Generator<br />

Max Power<br />

dBm<br />

Operating Manual 1313.9681.12 - 01 4.249