R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

DISPlay[:WINDow]:TRACe:X:SPACing LINear | LOGarithmic<br />

This command toggles between linear and logarithmic display.<br />

Example: "DISP:TRAC:X:SPAC LIN"<br />

Characteristics: *RST value: LOGarithmic<br />

SCPI: conform<br />

Mode: A<br />

The numeric suffix in TRACe is irrelevant.<br />

DISPlay[:WINDow]:TRACe:Y[:SCALe] 10dB to 200dB<br />

DISPlay Subsystem<br />

This command defines the display range of the y-axis (level axis) in the selected measurement window<br />

with logarithmic scaling (DISPlay[:WINDow]:TRACe:Y:SPACing).<br />

For linear scaling, the display range is fixed and cannot be modified. The numeric suffix at<br />

TRACe is irrelevant.<br />

Example: "DISP:TRAC:Y 110dB"<br />

Characteristics: *RST value: 100dB<br />

SCPI: device-specific<br />

Mode: A<br />

DISPlay[:WINDow]:TRACe:Y[:SCALe]:MODE ABSolute | RELative<br />

This command defines the scale type of the y-axis (absolute or relative) in the selected measurement<br />

window. SYSTem:DISPlay is set to OFF, this command has no immediate effect on the screen. The<br />

numeric suffix in TRACe is irrelevant.<br />

Example: "DISP:TRAC:Y:MODE REL"<br />

Characteristics: *RST value: ABS<br />

SCPI: device-specific<br />

Mode: A<br />

DISPlay[:WINDow]:TRACe:Y[:SCALe]:RLEVel -130dBm to 30dBm<br />

This command defines the reference level in the selected measurement window. Depending on the<br />

coupling of the measurement windows, it is valid for both screens or only for the selected measurement<br />

window (INSTrument:COUPle). The unit depends on the setting defined with the CALCulate:<br />

UNIT:POWer command.<br />

The numeric suffix at TRACe is irrelevant.<br />

If the reference level offset is not 0 (DISPlay[:WINDow]:TRACe:Y[:SCALe]:RLEVel:<br />

OFFSet), the indicated value range of the reference level is modified by the offset.<br />

Example: "DISP:TRAC:Y:RLEV -60"<br />

Characteristics: *RST value: -20<br />

SCPI: conform<br />

Mode: A<br />

6.112 Operating Manual 1313.9681.12 - 01