R&S <strong>FSQ</strong> Instrument Functions<br />

Basic Settings<br />

One limitation is, however, that software handshaking cannot be used for the transmission<br />

of binary data, since the control characters XON and XOFF require bit combinations<br />

that are also used for binary data transmission.<br />

Default setting is NONE.<br />

Remote command: SYST:COMM:SER:PACE NONE<br />

Owner – Assignment of the interface<br />

The serial interface can be assigned alternatively to the measuring instrument section<br />

or to the computer section.<br />

If the interface is assigned to one section of the instrument, it is not available to the<br />

other section.<br />

INSTRUMENTThe interface is assigned to the measuring instrument section.<br />

Outputs to the interface from the computer section are not possible<br />

and will get lost.<br />

OS The interface is assigned to the computer section. It cannot be<br />

used by the measuring instrument section. This means that<br />

remote control of the instrument via the interface is not possible.<br />

Setting Date and Time<br />

TIME+DATE The TIME+DATE softkey activates the entry of time and date for the internal realtime<br />

clock.<br />

Time - Input of time<br />

In the corresponding dialog box, the time is partitioned into two input fields so that<br />

hours and minutes can be entered independently.<br />

Remote command: SYST:TIME 21,59<br />

Date - Input of Date<br />

In the corresponding dialog box, the date is partitioned into 3 input fields so that day,<br />

month and year can be input separately.<br />

For the selection of the month, pressing a unit key opens a list of abbreviations<br />

wherein the desired month can be selected.<br />

Remote command: SYST:DATE 1009,03,01<br />

Configuration of Network Settings<br />

The instrument can be connected to an Ethernet LAN (local area network) by means<br />

of the LAN Interface. This allows data transmission via the network and the use of<br />

network printers. The network card is able to handle both 10 MHz Ethernet IEEE<br />

802.3 and 100 MHz Ethernet IEEE 802.3u.<br />

Operating Manual 1313.9681.12 - 01 4.189