R&S <strong>FSQ</strong> Instrument Functions<br />

<strong>Analyzer</strong> Mode<br />

TRACK BW The TRACK BW softkey defines the search bandwidth for signal tracking. The frequency<br />

range is symmetrical with respect to the center frequency.<br />

TRACK<br />

THRESHOLD<br />

Remote command: CALC:MARK:FUNC:STR:BAND 10KHZ<br />

The TRACK THRESHOLD softkey defines the threshold value for signal detection.<br />

The value is always entered as an absolute level value.<br />

Remote command: CALC:MARK:FUNC:STR:THR -70DBM<br />

SELECT TRACE The SELECT TRACE softkey selects the trace on which signal tracking is to be performed.<br />

SPAN<br />

SPAN<br />

MANUAL<br />

SWEEPTIME<br />

MANUAL<br />

Remote command: CALC:MARK:FUNC:STR:TRAC 1<br />

4.5.2 Setting the Frequency Span – SPAN Key<br />

The SPAN key opens a menu which offers various options for setting the span.<br />

The entry of the span (SPAN MANUAL softkey) is automatically active for span > 0<br />

Hz.<br />

For span = 0 Hz the entry for sweep time (SWEEPTIME MANUAL) is automatically<br />

active.<br />

With two windows (SPLIT SCREEN) displayed at the same time, the input data<br />

always refer to the window selected with the SCREEN A/B hotkey.<br />

SPAN MANUAL<br />

SWEEPTIME MANUAL<br />

FULL SPAN<br />

ZERO SPAN<br />

LAST SPAN<br />

FREQ AXIS (LIN LOG)<br />

The SPAN MANUAL softkey activates the window for manually entering the frequency<br />

span. The center frequency is kept constant.<br />

Allowed range of span values:<br />

• for the time domain (span = 0): 0 Hz<br />

• and for the frequency domain (span >0): minspan ≤ fspan ≤ fmax<br />

fspan frequency span<br />

minspan smallest selectable span (10 Hz)<br />

max. frequency<br />

fmax<br />

Remote command: FREQ:SPAN 2GHz<br />

The SWEEPTIME MANUAL softkey activates the window for entering the sweep<br />

time manually with Span = 0 Hz. The softkey is not available for Span > 0 Hz.<br />

Remote command: SWE:TIME 10s<br />

Operating Manual 1313.9681.12 - 01 4.13