R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Differences in GPIB Behavior between the FSP and the FSE Families of Instruments<br />

Devices Command (Sheet 36 of 47) Parameter Notes<br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

R&S<br />

<strong>FSQ</strong><br />

FSE [SENSe:]FREQuency:CENTer 0 to fmax frequency ranges are<br />

different for R&S <strong>FSQ</strong><br />

and FSE<br />

FSE [SENSe:]FREQuency:CENTer:LINK STARt | STOP | SPAN not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]FREQuency:CENTer:STEP 0 to fmax frequency ranges are<br />

different for R&S <strong>FSQ</strong><br />

and FSE<br />

FSE [SENSe:]FREQuency:CENTer:STEP:LINK SPAN | RBW | OFF<br />

FSE [SENSe:]FREQuency:CENTer:STEP:LINK:<br />

FACTor<br />

1 to 100 PCT<br />

FSE [SENSe:]FREQuency:MODE CW|FIXed | SWEep<br />

FSE [SENSe:]FREQuency:OFFSet <br />

FSET [SENSe:]FREQuency:RANGe 2 GHz | 22 GHz not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]FREQuency:SPAN 0 to fmax frequency ranges are<br />

different for R&S <strong>FSQ</strong><br />

and FSE<br />

FSE [SENSe:]FREQuency:SPAN:FULL<br />

FSE [SENSe:]FREQuency:SPAN:LINK CENTer | STOP | SPAN not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]FREQuency:STARt 0 to fmax frequency ranges are<br />

different for R&S <strong>FSQ</strong><br />

and FSE<br />

FSET [SENSe:]FREQuency:STARt:FLINe[:STATe] ON | OFF not available for<br />

R&S <strong>FSQ</strong>. Replaced by<br />

CALC:MARK:FUNC:<br />

SLIMits<br />

FSE [SENSe:]FREQuency:STARt:LINK CENTer | STOP | SPAN not available for<br />

R&S <strong>FSQ</strong><br />

FSE [SENSe:]FREQuency:STOP 0 to fmax frequency ranges are<br />

different for R&S <strong>FSQ</strong><br />

and FSE<br />

FSET [SENSe:]FREQuency:STOP:FLINe[:STATe] ON | OFF not available for<br />

R&S <strong>FSQ</strong>; replaced by<br />

CALC:MARK:FUNC:<br />

SLIMits.<br />

FSE [SENSe:]FREQuency:STOP:LINK CENTer | STARt | SPAN not available for<br />

R&S <strong>FSQ</strong><br />

FSET/<br />

ESIB<br />

FSET/<br />

ESIB<br />

[SENSe:]FREQuency[:CW|:FIXed] fmin to fmax not available for<br />

R&S <strong>FSQ</strong><br />

[SENSe:]FREQuency[:CW|:FIXed]:STEP fmin to fmax not available for<br />

R&S <strong>FSQ</strong><br />

[SENSe:]LIST:POWer:RESult? new function for<br />

R&S <strong>FSQ</strong><br />

6.318 Operating Manual 1313.9681.12 - 01