R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

Example: "CALC:MARK2:MAX"<br />

'Positions marker 2 in screen A to the maximum value of 'the trace.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

This command is an event and therefore has no *RST value and no query.<br />

CALCulate:MARKer:MAXimum:RIGHt<br />

CALCulate Subsystem<br />

This command positions the specified marker to the next smaller maximum value to the right of the<br />

current value (i.e. in ascending X values) on the corresponding trace.<br />

Example: "CALC:MARK2:MAX:RIGH"<br />

'Positions marker 2 in screen A to the next lower maximum value to the right of the<br />

current value.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

This command is an event and therefore has no *RST value and no query.<br />

CALCulate:MARKer:MINimum:AUTO ON | OFF<br />

This command switches an automatic minimum peak search for marker 1 at the end of each particular<br />

sweep on and off. The current marker search limit settings (LEFT LIMIT, RIGHT LIMIT, THRESHOLD,<br />

EXCLUDE LO) are taken into account. The numeric suffix at MARKer is irrelevant.<br />

Example: "CALC:MARK:MIN:AUTO ON"<br />

Activates the auto search function for marker 1.<br />

Characteristics: *RST value: OFF<br />

SCPI: device-specific<br />

Mode: A<br />

If no next smaller maximum value is found on the trace (level spacing to adjacent<br />

values < peak excursion), an execution error (error code: -200) is produced.<br />

CALCulate:MARKer:MINimum:LEFT<br />

This command positions the specified marker to the next higher minimum value to the left of the current<br />

value (i.e. in descending X direction) on the corresponding trace.<br />

If no next higher minimum value is found on the trace (level spacing to adjacent<br />

values < peak excursion), an execution error (error code: -200) is produced.<br />

Example: "CALC:MARK2:MIN:LEFT"<br />

'Positions marker 2 in screen A to the next higher minimum value to the left of the<br />

current value.<br />

6.48 Operating Manual 1313.9681.12 - 01