10.04.2013 Views

Complete Compiled Specification.pdf - Peck Ormsby Construction

Complete Compiled Specification.pdf - Peck Ormsby Construction

Complete Compiled Specification.pdf - Peck Ormsby Construction

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3. Place new pipe stub at line and grade and stubbed into new manhole location with pipe<br />

extending towards existing pipes.<br />

4. Place CMU blocks or other approved support adjacent to pipes to support new barrel<br />

section.<br />

5. Set first barrel section on CMU blocks and verify that barrel section is level in all<br />

directions and is not sitting on pipes.<br />

6. Make sure that hole is deep enough that the depth of concrete will be 9-inches below<br />

existing and new pipes.<br />

7. Place concrete around barrel section and inside barrel section so that the existing and<br />

new pipes are at least 50% covered with concrete.<br />

8. Hand form trough as needed.<br />

9. Let concrete cure and break out of pipes for trough. Grout all troughs smooth and even<br />

with pipes.<br />

10. Stack remaining barrel sections and add cone, ring and cover etc. as indicated for<br />

precast manhole.<br />

2.11 CONCRETE<br />

A. General: Cast-in-place concrete according to ACI 318/318R, ACI 350R, and the following:<br />

1. Cement: ASTM C 150, Type II.<br />

2. Fine Aggregate: ASTM C 33, sand.<br />

3. Coarse Aggregate: ASTM C 33, crushed gravel.<br />

4. Water: Potable.<br />

B. Cement Design Mix: 4000 psi minimum, with 0.45 maximum water-cementitious materials ratio.<br />

1. Reinforcement Fabric: ASTM A 185, steel, welded wire fabric, plain.<br />

2. Reinforcement Bars: ASTM A 615/A 615M, Grade 60, deformed steel.<br />

C. Ballast and Pipe Supports: Portland cement design mix, 3000 psi minimum, with 0.58<br />

maximum water-cementitious materials ratio.<br />

1. Reinforcement Fabric: ASTM A 185, steel, welded wire fabric, plain.<br />

2. Reinforcement Bars: ASTM A 615/A 615M, Grade 60, deformed steel.<br />

PART 3 - EXECUTION<br />

3.1 EARTHWORK<br />

A. Excavation, trenching, and backfilling are specified in Division 2 Section "Earth Moving."<br />

3.2 PIPING APPLICATIONS<br />

A. Pipe couplings and special pipe fittings with pressure ratings at least equal to piping rating may<br />

be used in applications below, unless otherwise indicated.<br />

1. Use nonpressure-type flexible couplings where required to join gravity-flow, nonpressure<br />

sewer piping, unless otherwise indicated.<br />

a. Flexible or rigid couplings for same or minor difference OD pipes.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION<br />

SANITARY SEWEAGE PIPING<br />

MARCH 2, 2009<br />

02608 - 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!