F. Galvanize exterior frames, hot dip, ASTM A-525 and A-526, Type I, Class D.<br />

2.02 METAL DOORS<br />

A. Construct to sizes shown; provide necessary clearances and bevels to permit operation<br />

without binding and to accommodate thresholds where required.<br />

B. Provide one-piece pan shaped face sheets of 16 gage material, spot welded to 20 gage<br />

reinforcing channels (18 gage at edges) which are spaced not over 8" o.c. and run full height<br />

of doors. Weld continuous 18 gage stiffener channels at top of all doors and close tops of<br />

exterior frames against water accumulation and make watertight. Pack spaces between<br />

reinforcing members with inorganic insulating material to sound deaden doors. Fill joints with<br />

mineral filler; finish surface smooth and flush. Bevel lock stile 1/8" in 2".<br />

1. Comply with requirements for SDI Grade III Extra Heavy-duty, Model 4 Seamless<br />

Composite.<br />

a. U Value: 0.09 (urethane core).<br />

C. Include reinforcements and mortising for required hardware specified under Section 08700<br />

from templates furnished thereunder. Reinforce butt cutouts with minimum 3/16" thick steel<br />

plate, drilled, tapped and welded in place.<br />

D. Fire rated doors shall be constructed to meet U.L. requirements and shall display label.<br />

E. Clean thoroughly, fill joints smooth, and prime with factory baked-on neutral gray rustinhibiting<br />

paint tested per ASTM D-174 and B-117.<br />

2.03 HARDWARE PREPARATION<br />

A. Make cutouts for required hardware specified Division 8 Section “Finish Hardware” from<br />

templates furnished thereunder. Reinforce butt cutouts with minimum 3/16" thick steel plate,<br />

drilled, tapped and welded in place. Provide strike stops on frames with holes for 3 rubber<br />

door silencers; on double door frames, provide for 2 silencers per door at head. Reinforce<br />

head section for installation of closers. Plaster guards shall be installed in back of all<br />

applicable hardware cutouts. Frames shall be reinforced for surface applied hardware.<br />

Reinforcement shall comply with S.D.I. recommendations.<br />

2.04 FINISHES<br />

A. Interior Doors & Frames: Phosphatized with one coat baked on rust inhibiting prime paint,<br />

ANSI A224.1.<br />

B. Exterior Doors & Frames: Galvanized, hot-dipped, ASTM A525, G60.<br />

C. Field paint, colors as selected by Architect.<br />

PART 3 - EXECUTION<br />

3.01 EXAMINATION<br />

A. Examine all subsurfaces to receive work and report, in writing, to the Architect, any conditions<br />

detrimental to work. Failure to observe this injunction constitutes a waiver to any subsequent<br />

claims to the contrary. Commencement of work will be construed as acceptance of all<br />

subsurfaces.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

HOLLOW METAL DOORS AND FRAMES 08100-2