SECTION 09900 - PAINTING<br />

PART 1 - GENERAL<br />

1.01 SUMMARY<br />

A. Supply and apply all painting work as specified on the drawings and included in this section.<br />

B. Mechanical and plumbing identification shall be by Division 15.<br />

C. Section includes painting work, interior and exterior. Work Includes, but is not limited to<br />

painting the following:<br />

1. Exterior steel including, but not limited to steel lintels and railings.<br />

2. Metal doors and door frames, including metal glazing stops.<br />

3. Removable mullions.<br />

4. Exterior metal mechanical units.<br />

5. Interior walls and ceilings.<br />

6. Interior steel rails and miscellaneous metal.<br />

7. Exposed structural steel.<br />

8. Exterior exposed metal flashing.<br />

9. Work includes field painting of exposed bare and covered pipes and ducts (including<br />

color coding), and of hangers, exposed steel and iron work, plug mold, electric<br />

panels, and primed metal surfaces of equipment installed under mechanical and<br />

electrical work, except as otherwise indicated. Field painting of a roof mounted<br />

mechanical units is part of this section. Field painting includes:<br />

a. Return air louvers.<br />

D. Related Sections: The following Sections contain requirements that relate to this Section:<br />

1. Division 3 Section “Concrete Work” for sealed concrete.<br />

2. Division 4 Section “Unit Masonry” for interior and exterior brick sealer.<br />

3. Division 5 Section “Metal Fabrications” for bollards, pipe railings, steel lintels and<br />

other miscellaneous metals.<br />

4. Division 8 Section “Hollow Metal Doors and Frames” for field painted metal doors and<br />

frames.<br />

5. Division 8 Section “Wood Doors” for field painted stops in wood doors.<br />

1.02 SURFACES NOT TO BE PAINTED<br />

A. Any gypsum wallboard permanently concealed from view.<br />

B. Any factory finished paneling, equipment and other materials with a complete factory applied<br />

finish, except where otherwise noted.<br />

C. Finish hardware, except where primed for paint finish.<br />

D. Factory finished wood doors.<br />

E. Non ferrous metals, unless specifically noted otherwise.<br />

F. Lighting fixtures, except as noted on the drawings or specified.<br />

G. Any acoustical surfaces, unless noted otherwise.<br />

H. Any glass, plastics, vinyl floor, ceramic tiles and top set base.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

PAINTING 09900 - 1