B. Materials and Finishes:<br />

1. For 16-gage and heavier units, fabricate metal framing components of structural<br />

quality steel sheet with a minimum yield point of 50,000 psi; ASTM A 446, A 570 or A<br />

611. See drawings for additional requirements.<br />

2. For 18-gage and lighter units, fabricate metal framing components of commercial<br />

quality steel sheet with a minimum yield point of 33,000 psi; ASTM A 446, A 570, or A<br />

611. See drawings for additional requirements.<br />

3. Provide galvanized finish to metal framing components complying with ASTM A 525<br />

for minimum G 60 coating. Finish of installation accessories to match that of main<br />

framing components, unless otherwise indicated.<br />

C. Fasteners: Provide nuts, bolts, washers, screws, and other fasteners with corrosion-resistant<br />

plated finish.<br />

D. Electrodes for Welding: Comply with AWS Code and as recommended by stud manufacturer.<br />

See drawings for additional requirements.<br />

E. Galvanizing Repair Paint: Where galvanized surfaces are damaged, prepare surfaces and<br />

repair in accordance with procedures specified in ASTM A 780.<br />

2.03 SHEATHING<br />

A. Glass-Mat Gypsum Sheathing Board with Water-Resistant Core for Vertical Roofed Areas:<br />

Gypsum sheathing board designed as an exterior substrate for a weather barrier, consisting<br />

of a noncombustible water-resistant core, essentially gypsum, surfaced with glass mats on<br />

face and back, partially or completely embedded in core, and with unsurfaced square edges.<br />

Comply with ASTM C 11 77 and requirements indicated below:<br />

1. Type: Regular/TypeX.<br />

2. Edge and End Configuration: Unsurfaced square.<br />

3. Thickness: 5/8 inch.<br />

4.<br />

A. Available Products: Subject to compliance with requirements, glass-mat gypsum sheathing<br />

boards that may be incorporated in the Work include, but are not limited to, the following:<br />

1. Glass-Mat Gypsum Sheathing Board:<br />

a. Dens-Glass Gold Exterior Sheathing; Georgia-Pacific Corp.<br />

B. Sheathing Fasteners: ASTM C 954, steel drill screws, Type S-12 fluted tip, a minimum of 1 -<br />

1/4 inches (32 mm) long, with organic-polymer coating or other corrosion-protective coating.<br />

C. Fire resistance:<br />

1. Noncombustible when tested in accordance with ASTM E 136.<br />

2. Flame spread 0, smoke developed 0, when tested in accordance with ASTM E 84.<br />

2.04 BUILDING PAPER<br />

A. No. 15, non-perforated, asphalt saturated felt complying with ASTM D 226, Type 1 or equal.<br />

2.05 ACCESSORIES<br />

A. Joint tape: 2" wide, 10x10 glass mesh tape.<br />

B. Joint compound: Manufacturer’s setting-type joint compound.<br />

C. Screws, metal framing:<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

COLD-FORMED METAL FRAMING 05400 - 3