B. Aluminum Extrusions:<br />

1. Perimeter Extrusions<br />

a. Alloy: AA-6063-T5<br />

b. Color: Extrusion color shall be black painted Duracon.<br />

2. Stiffeners<br />

a. Alloy: AA-6063-T5<br />

b. Color: Stiffeners shall have a mill finish.<br />

C. System Sealants:<br />

1. Sealants and gaskets within the panel system shall be per manufacturer's standards.<br />

2. Sealant color shall be black.<br />

D. Gaskets:<br />

1. Gaskets shall be Santoprene or EPDM.<br />

E. Flashings:<br />

1. Fabricate flashing from 0.062” minimum thickness aluminum sheet. Where exposed to<br />

view, finish to match adjacent panels. Provide lap strip under flashing at abutted<br />

conditions; with lapped surfaces sealed with a full-bed of non-hardening sealant.<br />

F. Fasteners:<br />

1. Attachment of the panel system to the primary panel structural supports shall be made<br />

using a Drill-Flex ! Fastener by ELCO Textron Inc.<br />

2. Typical joinery shall be attached with concealed fasteners. When exposed fasteners<br />

are required in isolated conditions, the fastener shall be obscured in the panel joinery.<br />

2.03 FABRICATION<br />

A. Fabricate panel units to dimensions indicated on the drawings based on an assumed design<br />

temperature of +70 degrees F. Allow for ambient temperature range at time of fabrication and<br />

erection.<br />

B. Fabricate panels in sizes shown using composite aluminum panel material and perimeter<br />

extrusion so that the panel thickness at the joinery is no more than 1.75". <strong>Complete</strong>d panel<br />

shall be properly fabricated and designed so that no restraints are placed on the panel, which<br />

might result in excessive compressive skin stresses. The installation detailing shall be such<br />

that the installed panels shall remain flat due to temperature changes and at all times remain<br />

water and air-tight. Oil canning of panel surface is not acceptable.<br />

C. Where practical, shop fabricate units ready for erection. If not shop assembled, pre-fabricate<br />

components at the shop as required for proper and expeditious field assembly.<br />

D. Design, fabricate, assemble, and erect wall panel units, to insure a weather tight system, as<br />

required in this specification section.<br />

E. Where drawings indicate, factory curve panels to required radii. Extrusions shall be factory<br />

stretched formed to conform to panel curve.<br />

F. Provide stiffeners secured to rear face of panels mechanically fastened to edge trim members,<br />

with spacing as required by specific job wind loading.<br />

________________________________________________________________________________________<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

COMPOSITE PANELS 07430 - 6