I. Operating Parts: Unless otherwise indicated, moving parts of operating units, mechanical and<br />

electrical pads, such as valve and damper operators, linkages, sinkages, and sensing<br />

devices. Do not paint motor and fan shafts.<br />

J. Code-required labels, such as Underwriters’ Laboratories and Factory Mutual, or any<br />

equipment identification, performance rating, name, or nomenclature plates.<br />

1.03 SAMPLES<br />

A. Submit samples of all types of finish specified herein.<br />

1. Before work is begun, Architect shall furnish a color schedule from manufacturer’s<br />

standard and specially requested color mixes.<br />

2. Product Data: Submit manufacturer’s technical information including Paint label<br />

analysis and application instructions for each material proposed for use.<br />

a. On 12” x 12” hardboard, provide two samples of each color and material, with<br />

texture to simulate actual conditions. Resubmit samples as requested by<br />

Architect until acceptable sheen, color, and texture is achieved.<br />

b. On actual wall surfaces and other exterior and interior building components,<br />

duplicate painted surfaces and other exterior and interior building<br />

components, on at least 100 sq. ft. Of surface, or as directed, until required<br />

sheen, color and texture is obtained; simulate finished lighting conditions for<br />

review of in-place work. Final acceptance of colors will be from samples<br />

applied on the job.<br />

1.04 QUALITY ASSURANCE<br />

A. Single Source Responsibility: Provide primers and other undercoat paint produced by same<br />

manufacturer as finish coats. Use only thinners approved by paint manufacturer, and use only<br />

within recommended limits.<br />

B. Coordination of Work: Review other sections of these specifications in which prime paints are<br />

to be provided to ensure compatibility of total coatings system for various substrates. Upon<br />

request from other trades, furnish information or characteristics of finish materials provided for<br />

use, to ensure compatible prime coats are used.<br />

1.05 DELIVERY AND STORAGE<br />

A. Deliver materials to job site in original, new and unopened packages and containers bearing<br />

manufacturer’s name and label, and following information:<br />

1. Name or title of material.<br />

2. Manufacturer’s stock number and date of manufacture.<br />

3. Manufacturer’s name.<br />

4. Contents by volume, for major pigment and vehicle constituents.<br />

5. Thinning instructions.<br />

6. Application instructions.<br />

7. Color name and number.<br />

B. Store materials not in actual use in tightly covered containers. Maintain containers used in<br />

storage of paint in a clean condition, free of foreign materials and residue.<br />

1. Protect from freezing where necessary. Keep storage area neat and orderly. Remove<br />

oily rags and waste daily. Take all precautions to ensure that workmen and work<br />

areas are adequately protected from fire hazards and health hazards resulting from<br />

handling, mixing and application of paints.<br />