SECTION 07900 - JOINT SEALANTS<br />

PART 1 - GENERAL<br />

1.01 RELATED DOCUMENTS<br />

A. Drawings and general provisions of Contract, including General and Supplementary conditions<br />

and Division 1 <strong>Specification</strong> Sections, apply to this Section.<br />

1.02 SUMMARY<br />

A. This section includes joint sealants for the following locations:<br />

1. Exterior Vertical Building Joints: Joints and cracks around window, aluminum<br />

entrances, door frames, columns, louvers, wall penetrations, connections, both sides<br />

and other joints necessary to seal off building from outside air and moisture. Perimeter<br />

edges of exterior insulation and finish system.<br />

2. Exterior Horizontal Surfaces.<br />

a. Sidewalk/pavement joints.<br />

b. Other joints as indicated.<br />

3. Interior Vertical and Horizontal Building Joints:<br />

a. Joints and cracks around wall, ceiling, and floor penetrations.<br />

b. Both sides of exterior and interior hollow metal door frames.<br />

c. Inside corners of gypsum board, fiber-reinforced wall sheathing and masonry.<br />

d. Perimeter joints of toilet fixtures.<br />

e. All transitions between differing building materials.<br />

f. Other joints as indicated.<br />

B. Related Sections: The following Sections contain requirements that relate to this Section:<br />

1. Division 7 Section “Exterior Insulation and Finish Systems” for sealing system joints.<br />

2. Division 7 Section “Flashing and Sheet Metal” for sealing joints related to flashing and<br />

sheet metal for roofing.<br />

3. Division 7 Section “Firestopping” for through-penetration firestopping systems.<br />

4. Division 7 Section “Built-Up Asphalt Roofing.”<br />

5. Division 7 Section “Polyvinyl-Chloride (PVC) Roofing.”<br />

6. Division 8 Section “Hollow Metal Doors and Frames.”<br />

7. Division 8 Section “Aluminum Entrances and Storefronts.”<br />

8. Division 8 Section “Glass and Glazing” for sealants used in glazing.<br />

9. Division 8 Section “Insulated Translucent Sandwich Panel Wall/Roof System.”<br />

10. Division 9 Section “Gypsum Board Assemblies” for sealing concealed perimeter joints<br />

of gypsum board partitions to reduce sound transmission.<br />

1.03 SYSTEM PERFORMANCE REQUIREMENTS<br />

A. Provide joint sealants for interior applications that have been produced and installed to<br />

establish and maintain airtight continuous seals that are water resistant and cause no staining<br />

or deterioration of joint substrates.<br />

1.04 SUBMITTALS<br />

A. General: Submit the following in accordance with Conditions of Contract and Division 1<br />

<strong>Specification</strong> Sections.<br />

B. Product data from manufacturers for each joint sealant product required.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

JOINT SEALANTS 07900-1