Power factor equal to or greater than 95%.<br />

Lamp starting at any light output setting.<br />

Meet all current Federal, State and Power Co. efficiency and efficacy standards, and<br />

rebate program requirements.<br />

Meet all current ANSI, IEEE, and FCC regulations for EMI/RFI, harmonic distortion,<br />

and transient protection.<br />

Provide normal lamp life as stated by lamp manufacturer.<br />

Minimum 5 year ballast and replacement labor warranty by manufacturer.<br />

Ballast manufacturer's data must be included with lighting fixture submittals.<br />

Compatible with occupancy sensor switching.<br />

Approved manufacturers: Advance (Mark 10), Lutron, or approved.<br />

Coordinate dimming ballasts with dimming controls specified in separate section.<br />

F. STANDARD COMPACT FLUORESCENT BALLASTS – PROGRAMMED START: Compact<br />

fluorescent ballasts, unless noted otherwise on Light Fixture Schedule, shall be programmed<br />

start electronic type; to operate 4 pin compact fluorescent lamps, ballast data as follows:<br />

UL listed and CSA certified.<br />

Full light output.<br />

Dual voltage rated 120/277<br />

Capable of operating more than one lamp wattage for PL-T triple tube applications<br />

Recognized Testing Laboratory listed, thermally protected, resetting, non-PCB,<br />

sound rated A.<br />

Operate lamp(s) at a frequency of above 40 kHz.<br />

Total Harmonic Distortion (THD) of less than 10%.<br />

Programmed start.<br />

Power factor equal to or greater than 98%.<br />

Maximum lamp crest factor 1.7.<br />

Minimum lamp starting temperature of 0 degrees F.<br />

Meet all current Federal, State and Power Company efficiency and efficacy<br />

standards, and rebate program requirements.<br />

Meet all current ANSI, IEE, and FCC regulations for EMI/RFI, harmonic distortion,<br />

and transient protection.<br />

Provide normal lamp life as stated by lamp manufacturer.<br />

Minimum 5 year ballast and replacement labor warranty by manufacturer.<br />

End-of-life detection and shut-down circuitry that meets proposed ANSI/IEC<br />

standards.<br />

Ballast manufacturer's data must be included with light fixture submittal.<br />

Approved manufacturers: Advance, Osram Sylvania, Magnetek, Howard Industries, or<br />

approved.<br />

G. HID ballasts shall be as follows:<br />

1. Metal Halide (MH):<br />

a. High power factor, normal ambient, 180 degrees C insulation class.<br />

b. Auto transformer with capacitor and ignitor for lamps 150 watt or less.<br />

c. Constant wattage autotransformer with capacitor for lamps above 150 watts.<br />

2. Pulse Start Metal Halide (PSMH):<br />