1. Supply pipe extending from wall shall be covered by chrome plated sleeve and wall flange.<br />

2. Additional wall plates shall be provided where each pipe extends through finished wall.<br />

3. Two rubber or plastic seat bumpers with metal holders shall be provided and secured to the<br />

wainscot behind the fixture.<br />

4. The centerline of the flush valve shall be on the centerline of the fixture, 39 inches above the<br />

finished floor and a minimum of 2-1/4 inches from the wall.<br />

5. Chrome plated pipe support shall be provided on the long flush pipe outlet and shall be secured<br />

rigidly to the wall with suitable anchors.<br />

6. The backflow preventer for the flush valve shall be installed at the discharge of the valves.<br />

7. The flush valve water piping concealed in the partition shall be rigidly supported; piping between<br />

flush valve and wall shall be provided with a factory fabricated chromium plated spacer sleeve and<br />

wall flange.<br />

LAVATORY INSTALLATION:<br />

General: Install lavatories as shown on the drawings and as follows:<br />

1. Lavatories for use by wheelchair handicapped shall be installed with a minimum rim height of 34", a<br />

minimum vertical clearance of 29" from floor, and a minimum clear knee recess of 30" in width and<br />

20" in depth.<br />

2. Trap on lavatory for use by wheelchair handicapped shall be installed so as to provide maximum<br />

clearance under bowl. Exposed waste, trap and hot water supply under lavatory shall be insulated<br />

in accordance with the requirements for domestic hot water piping.<br />

3. All lavatories shall be installed with a rim height of 34".<br />

URINAL INSTALLATION:<br />

General: Install urinals as shown on the drawing and as follows:<br />

1. Supply pipe extending from wall shall be covered by chrome plated sleeve and wall flange.<br />

2. Additional wall plates shall be provided where each pipe extends through finished wall.<br />

3. The centerline of the flush valve for wall hung urinals shall be on the centerline of the fixture, 45<br />

inches above the finished floor and a minimum of 2-1/4 inches from the wall.<br />

4. The centerline of the flush valve for handicap urinals shall be 40 inches or less above the finished<br />

floor.<br />

5. The backflow preventer for flush valve shall be installed at the discharge of the valve.<br />

6. The flush valve and the water piping concealed in the partition shall be rigidly supported; piping<br />

between flush valve and wall shall be provided with a factory fabricated chromium-plated spacer<br />

sleeve and wall flange.<br />

FIXTURE CONNECTIONS:<br />

Floor Mounted Water Closets and Service Sinks: Provide connections between soil pipes and floor<br />

connected water closets and service sinks made with cast-iron floor flanges.<br />

Connection sizes shall be 4-inch for water closets and 3-inch for service sinks.<br />

Floor flanges shall be slipped over the ends of the pipes and caulked in position.<br />