1.06 PROJECT CONDITIONS<br />

A. Field Measurements: Verify dimensions in system installation areas and indicate if<br />

dimensions on shop drawings are actual or guaranteed dimensions.<br />

1.07 WARRANTY<br />

A. General Warranty: Any warranties specified in this section shall not alter or change Owners<br />

rights and provisions received under other contract documents, and shall be in addition to<br />

those documents.<br />

B. Special Warranty: Provide system manufacturer provide written agreement to repair or<br />

replace all defective panel and system craftsmanship for a period of one (1) year from date of<br />

substantial completion. Provide Installer’s warranty against leakage for one (1) year from date<br />

of substantial completion.<br />

1.08 PRODUCT HANDLING<br />

A. Store panels on long edge, several inches above the ground, blocked and under cover to<br />

prevent damage. Follow manufacturer’s storage and handling instructions.<br />

PART 2 - PRODUCTS<br />

2.01 MANUFACTURERS<br />

A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering<br />

products that may be incorporated in the Work include, but are not limited to the following:<br />

1. Kalwall Corporation.<br />

B. Manufacturers wishing to bid this section must submit product information showing all<br />

compliance including IBC compliance in accordance with the ICBO reports and receive<br />

written approval prior to bidding.<br />

2.02 MATERIALS AND PANEL FABRICATION<br />

A. Translucent Fiberglass Faces: Manufactured from glass fiber reinforced thermoset resins by<br />

insulated system fabricator especially for architectural use. Thermoplastic (e.g.<br />

polycarbonate, acrylic) faces are not acceptable.<br />

B. Flammability: The interior face sheet shall be UL listed and have a flamespread rating no<br />

greater than 45 and smoke developed no greater than 350 when tested in accordance with<br />

UL 723. Burn extent by ASTM D-635 shall be no greater than 1". Faces shall not deform,<br />

deflect, drip when subject to fire or flame, or become detached when subjected to 300<br />

degrees F for 25 minutes.<br />

C. Weatherability: The full thickness of the exterior face shall not change color more than 3.0<br />

Hunter of CIE Units DELTA E by ASTM D-2244 after five (5) years outdoor South Florida<br />

weathering at 5 degrees facing south, determined by the average of at least three (3) white<br />

samples with and without a protective film or coating to insure maximum, long-term color<br />

stability.<br />

1. Class A Roof System: Seven (7) Units, after 30 months exposure.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION<br />

INSULATED TRANSLUCENT SANDWICH PANEL WALL/ROOF SYSTEM 08950 - 3