B. Power Supply Panel: Bosch No. RK-AL400 ULX. Provide power supply panel complete with<br />

the following item:<br />

1. Battery 18AH 12VFC.<br />

C. Provide the following field installed devices:<br />

1. Office Panic Switch.<br />

2. Proximity Card Reader; Bosch Corp AWID SP-6820<br />

D. Provide a laptop computer for client software Access Control System. Computer to be<br />

mounted in a lockable cabinet next to the Access Control Cabinet. The laptop shall meet the<br />

following minimum requirements:<br />

2.5 WIRING:<br />

1. 2.33 GHz Dual Core Processor<br />

2. 1 Gb of DDR2 ram<br />

3. 100Gb SATA hard drive (7200 RPM)<br />

4. 24X CD-RW/DVD Drive<br />

5. 128Mb video card<br />

6. 32 Bit Sound Card<br />

7. 1Gb Network interface card<br />

8. 15.4 TFT screen<br />

9. PC card: One Type I or Type II.<br />

10. I/O Ports: 2 USB 2.0, VGA, Serial<br />

11. Windows XP Pro Operating System.<br />

A. Provide the following wiring for the intrusion detection system components.<br />

1. ATM Keypad: 2 pair #18 twisted.<br />

2. Popit/Motion/ Door Contact: 2 pair #18 twisted.<br />

3. Network Switch: Two CAT6 cables.<br />

4. Fire Alarm Transponder: 2 #18.<br />

5. Access Control Panel: 8 #18.<br />

6. Phone Board: 8 #22, connected ahead of all other phone equipment.<br />

B. Provide the following wiring for the access control system components.<br />

PART 3 – EXECUTION<br />

1. Office Panic Switch: 2 pair #18 twisted<br />

2. Door Hardware Power Supply- Belden #638AFS Access Control Banana Peel Cable.<br />

3. Door Hardware Power Supply to the following:<br />

a. Card Reader; Belden #638AFS. Access Control Banana Peel Cable.<br />

b. Door Hardware; 1 pair #18 twisted.<br />

3.1 INSTALLATION OF SECURITY SYSTEM<br />

A. GENERAL: Install security system as indicated, in accordance with equipment<br />

manufacturers written instructions, and with recognized industry practices, to ensure that<br />

system equipment complies with requirements. Comply with requirements of NEC, and<br />

applicable portions of NECA's "Standards of Installation" practices.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION March 2, 2009<br />

SECURITY INTRUSION DETECTION AND ACCESS CONTROL SYSTEMS 16781-3