Downfeed Hot Water Supply: Each downfeed main for a hot water supply system shall be graded upward to<br />

the first branch connection, which shall be taken from the top of the main. Beyond the first connection the<br />

main shall grade downward, and all branch connections shall be taken from the bottom of the main.<br />

Connect a 1/2-inch circulating line to the bottom of each downfeed riser. Provide branch circuiting lines with<br />

gate valves in locations corresponding to the supply branch valve locations.<br />

Grading: Hot water supply and hot water circulating lines shall be accurately and uniformly graded to avoid<br />

traps which might impede or destroy circulation. All lines shall be graded so as to facilitate drainage.<br />

Unions: Unions shall be installed near points of connection to each piece of equipment, and elsewhere as<br />

required for installation of piping, removal and replacement of regulating and control equipment and the like.<br />

Right and left couplings or nipples are prohibited.<br />

Water Hammer Arresters: Water hammer arresters shall be provided where indicated on the drawings.<br />

Water hammer arresters shall be approved and installed in accordance with the requirements of<br />

PDI-WH201 and shall bear the PDI seal of approval.<br />

Roughing: Roughing shall be provided for equipment furnished under other sections of the specifications.<br />

Where future extensions are indicated on the drawings, roughing shall extend to within the space to be<br />

served, and shall be valved, and capped or plugged.<br />

___________________________________________________________________________________<br />

____________<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION March 2, 2009<br />

PLUMBING 15400-11