10.04.2013 Views

Complete Compiled Specification.pdf - Peck Ormsby Construction

Complete Compiled Specification.pdf - Peck Ormsby Construction

Complete Compiled Specification.pdf - Peck Ormsby Construction

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

M. The administrative phones shall be located in the office and where indicated on the plans;<br />

these phones shall be used for public and inter-school communication.<br />

N. The system shall allow room or area security monitoring features. This will include the ability<br />

to support motion detectors or normally open alarm inputs.<br />

2.3 EQUIPMENT AND MATERIALS:<br />

.<br />

A. CENTRAL CONTROLLER UNIT<br />

The Integrated Electronic Communications Network shall have the following capabilities:<br />

1. Facilities for multiple operations simultaneously without interference with an<br />

established pattern of priorities for all administrator/classroom communication<br />

capabilities.<br />

2. Provisions for Personal Identification Numbers for selected administrators. By dialing<br />

their PIN at any IP telephone, the administrator shall have access to the same<br />

intercom/paging capabilities assigned to their office IP telephone, regardless of the<br />

restrictions on the phone they are currently using.<br />

3. Provisions for multiple attendant positions for answering outside lines and internal<br />

intercom calls.<br />

4. Facilities for the central control unit to store information and give reports on features,<br />

system activity, etc. upon request either on site or remotely.<br />

5. Facilities for automatically sounding a warning tone signal over any loudspeaker<br />

selected for two-way communications to alert the station attendant (classroom<br />

teacher) to the call and prevent unauthorized monitoring.<br />

6. Facilities for access to any single loudspeaker unit, zone loudspeaker unit, or all<br />

loudspeaker units. The warning tone signal shall sound as soon as the station is<br />

selected and shall be automatically repeated at regular intervals for the duration of<br />

the call if the voice circuit is not activated.<br />

7. Direct Dialing, two-way amplified voice intercom between all locations equipped with<br />

administrative IP telephones and staff station speakers without the use of a<br />

press-to-talk or talk-listen switch.<br />

8. The Central Controller Unit shall provide an RS-232 port for the connection of on-site<br />

or off-site diagnostics by distributor or factory-trained personnel.<br />

a. This port shall be usable for the programming and saving of all programmed data<br />

for each system with the utilization of an on-site or off-site computer.<br />

b. This port shall provide the capability of logging of various activities within the<br />

system.<br />

9. Facilities for executive override permitting an assigned telephone to "override"<br />

on-going intercom conversation(s) in the system.<br />

10. Facilities for the instantaneous distribution of emergency announcements<br />

simultaneously, by a single button access, to all locations equipped with speakers.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION March 2, 2009<br />

INTEGRATED ELECTRONIC COMMUNICATION NETWORK 16760-7