(1) All costs resulting from modifications to the structure, substrates<br />

and/or other components as required by the proposed substitution.<br />

Each and every cost shall be clearly delineated in the submittal.<br />

B. Post-bid submittals:<br />

1. Shop Drawings: Submit CAD generated shop drawings showing profiles of panel units,<br />

details of forming, joint supports, anchorages, trim, flashings, sealants and accessories.<br />

Show details of weatherproofing at edge terminations, show elevations, and layout of<br />

entire work.<br />

a. Shop drawings should indicate project layout from control gird lines and<br />

elevations referring to the required details for each unique condition.<br />

b. The details should show the preferred profiles and performance requirements.<br />

Provide a watertight and structurally sound, self-draining wall panel system<br />

that meets or exceeds the performance criteria set in the Testing Section 1.05.<br />

2. Samples: Submit an 8" x 8" sample of panel system in the specified finish complete<br />

with factory applied edge treatment, fabricated into units representative of the actual<br />

system.<br />

3. Test Reports: Submit certified test reports which meet or exceed the requirements as<br />

described in the Testing Section 1.05. The test report shall include the following,<br />

a. Name and location of the certified independent testing laboratory with the<br />

contact phone numbers.<br />

b. Date the test was performed.<br />

c. Unit description and system name of the panel system tested. Include the test<br />

drawings with elevations with details showing the tested panel joinery.<br />

4. Report of Approval: ICC/EC Evaluation Report No. ESR-1114.<br />

5. Affidavit: Certifying material meets requirements specified.<br />

1.04 QUALITY ASSURANCE<br />

A. Qualifications:<br />

1. Installer qualifications: Installer experienced in performing work of this section who has<br />

experience in wall applications similar to that required for this project.<br />

a. Installation History: Installer shall be a firm that has at least five (5) years of<br />

experience with exterior wall applications and has successfully completed<br />

installations of similar scope and size to this project.<br />

2. Fabricator Qualifications: Fabricator capable of providing field service representation<br />

during construction, approving acceptable installer and application method.<br />

a. Fabrication History: Panel fabricator shall assume undivided responsibility for<br />

all components of the panel work, and shall demonstrate no less than ten (10)<br />

years successful experience of metal panel work similar in scope and size to<br />

this project.<br />

3. Manufacturer Qualifications: Manufacturer experienced in performing work of this<br />

section that has experience with the specified materials.<br />

a. Manufacturer of the composite material must have at least ten (10) years<br />

experience in the production of the specified composite material.<br />

b. ICC/EC Report: Composite panel manufacturer shall have an ICC/EC<br />

Research Report (i.e., Report ESR-1114 for Alucobond PE Core ! ).<br />

c. Certification: Composite panel manufacturer shall have established a<br />

Certification Program acceptable to the local Code Authorities.<br />

d. Manufacturers of the accessories and perimeter framing extrusions must have<br />

at least five (5) years experience in the production of their respective products.<br />

________________________________________________________________________________________<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

COMPOSITE PANELS 07430 - 2