SECTION 04200 - UNIT MASONRY<br />

PART 1 - GENERAL<br />

1.01 SUMMARY<br />

A. Section includes reinforced hollow clay brick and related items necessary to complete the<br />

work and thin brick for application at the new hallway in the existing building.<br />

1. This section includes interior and exterior brick sealers.<br />

B. Related Sections:<br />

1. Refer to Division 3 Section “Concrete Work” for reinforcing, except for horizontal joint<br />

reinforcement. Furnish and install reinforcement under this section.<br />

2. Refer to Division 7 Section “Sheet Membrane Waterproofing” for waterproofing<br />

system installed at masonry exposed to earth.<br />

C. Materials installed in this section but furnished by other Sections: anchors, bolts, sleeves for<br />

all piping, electrical conduits, outlet boxes, etc.<br />

D. Concrete Masonry Units: Substitution of concrete masonry units for brick, where brick<br />

is not exposed to view is permitted only where indicated in the drawings.<br />

1.02 SUBMITTALS<br />

A. Samples:<br />

1. Submit two samples of each type of unit masonry specified.<br />

2. Provide masonry sample panel, 4 ft. x 4 ft., erected with tooling, mortar, color and<br />

workmanship to represent actual work. Final brick selection shall be made only<br />

following architect’s review of sample panel. Brick from manufactured material for<br />

project shall be shipped to site and sample panel erected. No brick shall be shipped<br />

from manufacturer to site until architect’s acceptance of job panel which has been<br />

erected from actual material for project. This panel shall replace the sample panel<br />

and shall remain on site throughout construction, and become the project standard<br />

for bond, mortar, workmanship, and appearance.<br />

3. Submit test report and certificate of conformance document for each type and color of<br />

brick specified on contract documents for architect’s approval.<br />

4. Test reports shall include:<br />

a. Compressive strength<br />

b. 24 hour cold water absorption<br />

c. 5 hour boil absorption<br />

d. Saturation Coefficient<br />

e. Initial Rate of Absorption (I.R.A.)<br />

f. Efflorescence<br />

g. Weather classification<br />

5. Certificate of conformance shall state that brick meets or exceeds applicable ASTM<br />

specifications indicated herein.<br />

1.03 QUALITY ASSURANCE<br />

A. Verify all measurements shown on the drawings by taking field measurements; proper fit and<br />

attachment of all unit masonry is required.<br />

B. Coordinate with other trades whose work relates to unit masonry installation for the placing of<br />

all required blocking, sub-framing, backing, furring, etc., to ensure proper location and<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

UNIT MASONRY 04200-1