2.02 FINISH<br />

E. Solder: Grade A, ASTM B-32, composed of 50% pig lead and 50% block tin, warranted pure.<br />

No re-melted or reworked solder shall be used.<br />

F. Flux: Muriatic acid killed with zinc, or an approved brand of soldering flux, for galvanized<br />

steel; rosin for copper. Flux shall be thoroughly washed off after soldering is completed.<br />

G. Cement: Bituminous plastic, FS-SS-C-153.<br />

H. Building paper: Waterproof, FS-UU-P-147.<br />

I. Sealant: Morrison and Company CL-50 polyisobutylene. Include primer as required.<br />

J. Butyl sealer: Where impractical to use solder at joints, corners, and transitions, seal with DAP<br />

"Butyl Gutter and Lap Sealer" or "Cushion Lock CL-50 Butyl Sealer" - Black color.<br />

K. Asphalt primers: FS-SS-A-701.<br />

L. Coating Asphalt: Brushing consistency, FS-SS-R-451.<br />

M. Reglets: Fry Reglet Corporation springloc flashing system, Type SM surface mounted with<br />

Mono, one part acrylic sealant, Type CO concrete, and Type MA masonry.<br />

N. Primer on ferrous metal: FS TT-P-645.<br />

A. Finish shall be full strength Kynar 500 Fluoropolymer coating, applied by the manufacturer on<br />

a continuous coil coating line, with a top side dry film thickness of 0.70 to 0.90 mil over 0.25<br />

to 0.35 mil prime coat, to provide a total dry film thickness of 0.95 to 1.25 mil. Bottom side<br />

shall be coated with primer with a dry film thickness of 0.25 mil. Finish shall conform to all<br />

tests for adhesion, flexibility, and longevity as specified by the Kynar 500 finish supplier.<br />

1. Color: As selected by Architect from manufacturer’s standard or custom colors.<br />

2.03 FABRICATION<br />

A. Fabricate sheet metal flashing to shapes and sizes detailed, allowing sufficient materials for<br />

up-standing leg. Make surfaces free of waves and buckles with lines, arises, and angles<br />

sharp and true.<br />

PART 3 - EXECUTION<br />

3.01 EXAMINATION<br />

A. Examine all subsurfaces and report, in writing, to the Architect any conditions detrimental to<br />

the work. Failure to observe this injunction constitutes a waiver to any subsequent claims.<br />

Commencement of work will be construed as acceptance of all subsurfaces.<br />

3.02 INSTALLATION<br />

A. Conform to quality, procedures and methods recommended by National Association of Sheet<br />

Metal Contractors. Accurately form, fit snugly, fold exposed edges under at least !" and have<br />

no sharp corners left exposed. Properly shield against galvanic action with asphalt base paint<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

FLASHING AND SHEET METAL 07600-2