D. Exterior Face: Provide a permanent glass veil erosion barrier integrally embedded to provide<br />

maximum long-term resistance to fiber exposure. Substitute plastic surface films, coatings or<br />

veils not acceptable.<br />

E. Face Sheets: Provide smooth face sheets with maximum variation in thickness of not more<br />

than plus or minus 10% and uniform in color.<br />

1. Exterior Face Sheet:<br />

a. Thickness: 0.070"<br />

b. Color: Crystal.<br />

2. Interior Face Sheet:<br />

a. Thickness: 0.045".<br />

b. Color: White.<br />

F. Panel System: 2-3/4" thick, made of two sheets of translucent fiberglass, bonded by heat and<br />

pressure to either an aluminum or composite grid core specifically for architectural use.<br />

G. Thermal Insulation: Provide NFRC laboratory tested and certified system:<br />

1. “U” Factor: 0.29 by ASTM C-236, E-1423 and C-1199.<br />

H. Light & Solar Transmission per ASTM E-972:<br />

1. Light Transmission: 20<br />

2. Shading Coefficient: 0.219.<br />

I. Grid Cores:<br />

1. Grid Pattern: Symmetrical about the horizontal centerline for each flat panel:<br />

a. Nominal 12” x 12", square.<br />

2. Panels shall withstand 1200 degrees F fire for minimum (1) hour without collapse or<br />

exterior flaming.<br />

J. Adhesive:<br />

1. Laminate Adhesive: Heat and pressure resin-type engineered for structural sandwich<br />

panel use, with minimum 25 years field use, and passing testing requirements<br />

specified by the International Conference of Building Officials “Acceptance Criteria for<br />

Sandwich Panel Adhesive.”<br />

2. Minimum Strength: 750 PSI tensile strength by ASTM C-297 after two (2) exposures<br />

to six (6) cycles each of the aging conditions prescribed by ASTM D-1037.<br />

3. Shear strength by ASTM D-1002 minimum after exposures to five (5) separate aging<br />

conditions:<br />

a. 50% Relative Humidity at 73 degrees F: 540 PSI<br />

b. 182 degrees F: 100 PSI<br />

c. Accelerated Aging by ASTM D-1037 at room temperature: 800 PSI<br />

d. Accelerated Aging by ASTM D-1037 at 182 degrees F: 250 PSI<br />

e. 500-hour Oxygen Bomb by ASTM D-572: 1400 PSI<br />

K. Impact Resistance:<br />

1. Exterior Face Sheet: Uniform in strength and repel an impact equal to 60 ft. lbs.<br />

without fracture or tear when impacted by 3-1/2" diameter, 6.37 lb. free-falling ball,<br />

and be resistant to penetration by pencil point.<br />

L. Translucent Structural Sandwich Panel: True sandwich panel of flat fiberglass sheets bonded<br />

to a grid core of mechanically interlocking I-beams, laminated under a controlled process of<br />

heat and pressure, and deflect no more than 1.9" at 30 psf in 10' by ASTM E-72.<br />

M. The adhesive bonding line shall be straight, cover the entire width of the I-beam, and have a<br />

neat, sharp edge. In order to insure bonding strength, white spots at intersections of mutins<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION<br />

INSULATED TRANSLUCENT SANDWICH PANEL WALL/ROOF SYSTEM 08950 - 4