F. Lead content in pigment, if any, is limited to contain not more than 0.06% lead, as lead metal<br />

based on the total non-volatile (dry-film) of paint by weight.<br />

1. This limitation is extended to interior surfaces and those exterior surfaces, such as<br />

stairs, decks, porches, railings, windows, and doors which are readily accessible to<br />

children under seven years of age.<br />

2.03 PAINT SCHEDULE<br />

A. General: Provide the following paint systems for the various substrates, as indicated. Sherwin-<br />

Williams products are listed below to indicate paint system types, and to establish minimum<br />

requirements, but are not intended to limit the choice of manufacturers.<br />

1. Interior Gypsum Board.<br />

a. 1 st coat: PrepRite 200 Latex Primer, B28W200 (4 mils wet, 1.2 mils<br />

dry)<br />

b. 2 nd coat: ProMar 200 Interior Latex Eg-shel, B20W200<br />

c. 3 rd coat: ProMar 200 Interior Latex Eg-shel, B20W200 Series<br />

(4 mils wet, 1.6 mils dry per coat)<br />

2. Interior Concrete and Concrete Masonry Walls<br />

a. 1st coat: PrepRite Block Filler, B25W25 (16 mils wet, 8 mils dry)<br />

b. 2nd coat: ProMar 200 Interior Latex Eg-shel, B20W200<br />

c. 3rd coat: ProMar 200 Interior Latex Eg-shel, B20W200 Series<br />

(4 mils wet, 1.6 mils dry per coat)<br />

3. Interior Miscellaneous Ferrous Metal (Doors, H.M. jambs, exposed pipe, machinery,<br />

etc.)<br />

a. 1 st coat: Kem Kromik Universal Primer, B50Z Series (6 mils wet, 3<br />

mils dry)<br />

b. 2 nd coat ProMar 200 Alkyd Semi-Gloss, B34W200<br />

c. 3 rd coat: ProMar 200 Alkyd Semi-Gloss, B34W200 Series<br />

(4 mils wet, 1.7 mils dry per coat)<br />

4. Exterior Ferrous Metal<br />

a. 1 st coat: Kem Kromik Universal Metal Primer, B50Z Series (6 mils<br />

wet, 3 mils dry)<br />

b. 2 nd coat Industrial Enamel, B54Z Series<br />

c. 3 rd coat: Industrial Enamel, B54Z Series<br />

(4 mils wet, 2 mils dry per coat)<br />

5. Galvanized Ferrous Metal<br />

a. 1 st coat: Galvite HS, B50WZ30 (7 mils wet, 4.5 mils dry)<br />

b. 2 nd coat: Industrial Enamel, B54Z Series<br />

c. 3 rd coat: Industrial Enamel, B54Z Series (4 mils wet, 2 mils dry per<br />

coat)<br />

6. Metal Roof Deck (primed)<br />

a. 1 st coat: Super Save Lite Dryfall<br />

b. 2 nd coat: Super Save Lite Dryfall<br />

PART 3 - EXECUTION<br />

3.01 EXAMINATION<br />

A Applicator must examine areas and conditions under which painting work is to be applied and<br />

notify Contractor in writing of conditions detrimental to proper and timely completion of work.<br />

Do not proceed with work until unsatisfactory conditions have been correct in a manner<br />

acceptable to Applicator.<br />

B. Starting of painting work will be construed as Applicator’s acceptance of surfaces and<br />