2) Fittings: wrought copper, solder joint type<br />

3) Joints shall be soldered with silver solder, 45% silver, 15% copper, 16% zinc, 24%<br />

admium, solidus at 1125ø and liquids at 1145ø F.<br />

F. Gate Valves:<br />

1) Gate valves 3" and smaller shall meet the following requirements.<br />

a. Gate valve shall be 125 lb. SWP bronze gate valve with screw-in bonnet,<br />

non-rising stem, and solid wedge disc.<br />

b. Gate valve shall have threaded ends and shall be equipped with a bronze<br />

handwheel.<br />

c. Gate valve shall be similar to those manufactured by Nibco or approved<br />

equal.<br />

2) All gate valves shall be installed per installation details.<br />

G. Quick Coupling Valves:<br />

1) Quick coupling valves shall have a brass, one or two-piece body designed for<br />

working pressure of 150 P.S.I.<br />

2) Quick coupling valve shall be operable with a quick coupler key. Key size and type<br />

shall be as shown on the Drawings.<br />

3) Quick coupling valves used on domestic water systems shall be equipped with a<br />

thermoplastic rubber cover yellow in color.<br />

H. Back flow Prevention Unit: (Domestic Water Systems Only)<br />

1) Back flow prevention unit shall be of size and type indicated on the irrigation<br />

drawings. Install backflow prevention unit in accordance with irrigation<br />

construction details.<br />

2) Wye strainers at backflow prevention units shall have a bronzed screwed body with 0<br />

mesh monel screen and shall be similar to Bailey #100B or approved equal.<br />

3) All pressure main line piping between the point of connection and the backflow<br />

preventer shall be installed as required by local code. The Contractor shall verify<br />

with the local governing body as to material type and installation procedures prior to<br />

start of construction. Submit shop drawing for approval.<br />

I. Check Valves:<br />

1) Swing check valves 2" and smaller shall be 200 lb. W.O.G. bronze construction with<br />

replaceable composition, neoprene or rubber disc and shall meet or exceed Federal<br />

<strong>Specification</strong> WW-V-51d, Class A, Type IV.<br />

2) Anti-drain valves shall be of heavy duty virgin PVC construction with F.I.P. thread<br />

inlet and outlet. Internal parts shall be stainless steel and neoprene. Anti-drain valve<br />

shall be field adjustable against draw-out from 5 to 40 feet of head. Anti-drain valve<br />

shall be similar to the Valcon "ADV" or approved equal.<br />

J. Control Wiring:<br />

1) Wiring shall occupy the same trench and shall be installed along the same route as<br />

pressure supply or lateral lines wherever possible.<br />

2) Where more that one (1) wire is placed in a trench, the wiring shall be taped<br />

together at intervals of ten (10) feet.<br />

3) An expansion curl shall be provided within three (3) feet of each wire connection.<br />

Expansion curl shall be of sufficient length at each splice connection at each electric<br />

control, so that in case of repair, the valve bonnet may be brought to the surface<br />

without disconnecting the control wires. Control wires shall be laid loosely in trench<br />

without stress or stretching wire conductors.<br />

________________________________________________________________________<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

UNDERGROUND IRRIGATION SYSTEMS 02810-6