4) All splices shall be made with Scotch-Lok #3576 Connector Sealing Packs,<br />

Rainbird Snap-Tite wire connectors, or approved equal. Make only one splice with<br />

each connector sealing pack.<br />

K. Electric Control Valve:<br />

1) All electric control valves shall be the same size and type shown on the Drawings.<br />

2) All electric control valves shall have a manual flow adjustment.<br />

3) Provide and install one control valve box for each electric control valve.<br />

L. Valve Box:<br />

1) Use 10" x 10" round box with cover for all gate valves. Extension sleeve shall be PVC<br />

with minimum size of six (6) inches.<br />

2) Use jumbo valve box (nominal) rectangular box with cover for all electric control<br />

valves. Refer to Detail.<br />

3) Use 10" x 10" deep round plastic valve box for all quick coupling valves, Brooks<br />

#1100 with snap lock cover or approved equal.<br />

M. Bubbler Head:<br />

1) Riser units shall be fabricated in accordance with the installation details.<br />

2) Riser nipples for all bubblier heads shall be the same size as the riser opening in the<br />

sprinkler body.<br />

3) All bubblier heads of the same type shall be by the same manufacturer.<br />

N. Drip Emitters, Emitter Tubing, and Fittings:<br />

1) Emitter body shall be manufactured of durable plastic construction resistant to ultraviolet<br />

rays and a highly inert silicone elastometer diaphragm which is resistant to<br />

chemicals. The emitter shall have a color coded inlet barb to identify flow rate and<br />

shall be pressure compensating for a rated flow of + 10% over a pressure variant of<br />

15 to 45 P.S.I. Emitters shall be manufactured by Rainbird.<br />

2) Non-pressure lateral line piping for drip systems shall be Class 200.<br />

3) Provide AG Products 3/4" ball valve installed with flexible drip tubing and SMT 3/4"<br />

MHT by Spin LOC at terminus of each run. Install in 10" x 10" round box. Refer to<br />

Detail.<br />

4) Provide filtration and pressure regulation for each drip system. Rrefer to drawing for<br />

equipment types and sizes required.<br />

O. Secondary Water Filtration: Provide Clemons Model #1200A filter with galvanized<br />

housing and stainless steel screen. Upsize filter one pipe size larger than the line to<br />

the pipe.<br />

P. Miscellaneous Irrigation Equipment:<br />

1) Refer to the Drawings for sizes and types of miscellaneous irrigation equipment.<br />

2) All miscellaneous irrigation equipment shall be as specified or approved equal.<br />

IRRIGATION - EXECUTION<br />

3.01 OBSERVATION OF SITE CONDITIONS<br />

A. All scaled dimensions are approximate. The Contractor shall check and verify all size<br />

dimensions and receive approval from the Owner's Authorized Representative prior to<br />

proceeding with work under this Section.<br />

________________________________________________________________________<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

UNDERGROUND IRRIGATION SYSTEMS 02810-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!