10.04.2013 Views

Complete Compiled Specification.pdf - Peck Ormsby Construction

Complete Compiled Specification.pdf - Peck Ormsby Construction

Complete Compiled Specification.pdf - Peck Ormsby Construction

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SECTION 07240 - EXTERIOR INSULATION AND FINISH SYSTEM<br />

PART 1 - GENERAL<br />

1.01 SUMMARY<br />

A. Section includes exterior insulation and finish system, class PB, including but not limited to,<br />

finish, rigid insulation, mesh, primer, caulking and backing board when not shown on the<br />

drawings and required by manufacturer.<br />

B. Related Sections: Division 5 Section “Cold-Formed Metal Framing” for metal studs and<br />

sheathing.<br />

1.02 SUBMITTALS<br />

A. Refer to Section 01300. Submit shop drawings which show layout, installation methods and<br />

construction details.<br />

B. Submit 12" x 12" sample of full system on substrate identical to project requirements for type<br />

of finish. Sample shall be erected with same tools and techniques for actual work. Sample<br />

shall be used as a standard for color, finish, texture, and construction detailing of actual work.<br />

1.03 COORDINATION<br />

A. Coordinate with trades whose work is affected by the work of this section. Notify trades of<br />

schedule to ensure timely installation of items connected with this section.<br />

B. Work closely with Section 07600 to assure timely erection of flashing on exposed edges of<br />

system.<br />

1.04 DELIVERY AND STORAGE<br />

A. Deliver materials to site in manufacturer's original unopened packages with labels intact.<br />

B. Store materials in accordance with manufacturer's recommendations, protected from weather<br />

and temperatures below 40 degrees F.<br />

1.05 QUALITY ASSURANCE<br />

A. Manufacturer shall be a member of the Exterior Insulation Manufacturer's Association (EIMA).<br />

B. The applicator shall be certified by the manufacturer and have five years experience in the<br />

installation of exterior insulation finish systems.<br />

PART 2 - PRODUCTS<br />

2.01 MANUFACTURER & FINISH<br />

A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering<br />

products that may be incorporated in the Work include, but are not limited to the following:<br />

1. Dryvit Systems Inc.<br />

2. Sto Industries Inc.<br />

3. Synergy<br />

4. Master Wall Inc.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

EXTERIOR INSULATION AND FINISH SYSTEM 07240 - 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!