A General: Comply with NAAMM “Metal Finishes Manual” for recommendations relative to<br />

application and designations of finishes.<br />

B. Finish designations prefixed by ‘AA’ conform to the system established by the Aluminum<br />

Association for designating aluminum finishes.<br />

C. Class 1 Clear Anodized Finish: AA-M12C22A41 (Mechanical finish: as fabricated, non-specular;<br />

Chemical finish: etched, medium matter; Anodic Coating: Class 1 Architectural, clear anodic<br />

coating, minimum 0.7 mil thickness, complying with AAMA 611.<br />

2.04 SCHEDULED HARDWARE<br />

A. Requirements for design, grade, function, finish, size, and other distinctive qualities of each type<br />

of finish hardware are indicated in the “Hardware Schedule” at the end of this Section.<br />

B. Manufacturer’s Product Designations: The product designations and name of one manufacturer<br />

are listed for each hardware type required for the purpose of establishing minimum requirements.<br />

Provide either the product designated or, where more than one manufacturer is specified above,<br />

the comparable product of one of the other manufacturers that complies with requirements.<br />

C. Make cutouts for required hardware specified under Section 08700 from templates furnished<br />

there under. Factory machine and finish for all hardware.<br />

PART 3 - EXECUTION<br />

3.01 INSTALLATION (FRAMES)<br />

A. Storefront components shall be set in prepared openings. Frames shall be set plumb, level, and<br />

square. Sections installed in contact with steel or other dissimilar materials shall receive a heavy<br />

coat of bituminous paint to insulate the two surfaces.<br />

B. Aluminum frame for storefront glass shall be a “front-loaded” system. Profile of the frame may<br />

vary from each manufacturer; however the proposed system must consider the heights and<br />

lateral loading in effect to render the system stiff enough to withstand those forces and still allow<br />

for roof load deflection. Refer to storefront wall sections for size, height and suggested profiles of<br />

the storefront system.<br />

3.02 INSTALLATION (DOORS)<br />

A. Hang doors in adequately secured, square and plumb frames. After erection and glazing, check<br />

and adjust all operating hardware.<br />

B. Hardware for doors in Division 8 Section “Finish Hardware” shall be furnished by the aluminum<br />

door supplier (except cylinders) and installed on the door at the factory by the door manufacturer.<br />

C. Door manufacturer shall provide door bottoms, sweeps, weatherstripping, and piles at meeting<br />

strikes.<br />

3.03 CLEANUP<br />

A. Refer to Section 01700.<br />

B. Protect all exposed aluminum surfaces from staining or abrasion after installation.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

ALUMINUM ENTRANCES AND STOREFRONTS 08400 - 3