flanges of obstructions. Extend carpet under movable furniture and equipment, unless<br />

otherwise indicated.<br />

C. Install carpet edge guard at locations where edge of carpet is exposed to traffic or where floor<br />

covering materials change, except where another device, such as an expansion joint or<br />

threshold is indicated, with integral carpet binder bar or edge guard. Anchor edge guard to<br />

substrate.<br />

3.05 CLEANING AND PROTECTION<br />

A. Refer to Section 01700.<br />

B. Provide the Owner with a manual of instructions for proper care and cleaning of carpet.<br />

C. Remove spots, smears, stains, etc., immediately with a material recommended by carpet<br />

installation.<br />

D. After installation, sweep and vacuum carpet surfaces clean of all foreign material. Neatly<br />

apply minimum 4 mil thick polyethylene film, firmly fastened to carpet surfaces that are subject<br />

to construction traffic.<br />

E. Remnants: At direction of Architect, leave remnants, of sizes indicated, in possession of<br />

Owner.<br />

END OF SECTION<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

CARPET 09680 - 4